12075 NW 40th Street #6
Coral Springs, FL 33065
877-574-1738

Job Locations
for pompano beach, fl


Map of Pompano Beach FL
Nick G.

Nick G.


Job Checkin

MAIN LUG CIRCUIT PANEL- 1)——Remove 200 amp indoor main lug circuit panel. 2)——Replace with new 200 amp indoor 42 circuit main lug panel. 3)——Label,rough patch and clean. NOTE: The exsitng panel is to small and has no spaces left for the work needing to be done to bring kitchen up to code as we will need to add circuits and install 24 arc fault breakers in total to new circuits and exisitng to do so. DEDICATED CIRCUITS- 1)——Run dedicated 20 amp circuit from panel to microwave location. (Approximately 70ft) 2)——Run dedicated 20 amp circuit from panel to cooler location. (Approximately 70ft) 3)——Run dedicated 20 amp small appliance circuit from panel to 1 set of counter top outlets in kitchen. (Approximately 70ft) Code requires 2 small appliance circuits in kitchen, right now there is only 1. 4)——Run dedicated 40 amp cook top circuit from panel to cook top location. (Approximately 70ft) Cook top and oven are wired to same circuit that is not big enoug