Shane C.

Shane C. Job Checkin

Upon arrival I completed a Full Install of a Carrier 96% Gas Furnace 59SC5 (Up to 100,000 BTU) Honeywell T6 Programmable Thermostat/Emerson 1F85U Carrier 16 SEER Air Conditioner 24ABC6 (Up to 3 ton) The system is operational upon departure.

Upon arrival I completed a Full Install of a Carrier 96% Gas Furnace 59SC5 (Up to 100,000 BTU) Honeywell T6 Programmable Thermostat/Emerson 1F85U Carrier 16 SEER Air Conditioner 24ABC6 (Up to 3 ton) The system is operational upon departure.

Jacob M.

Jacob M. Job Checkin

Upon arrival I spoke with the customer stated a power surge happened the other day, tripped breaker, no ac since. I called for cooling, breaker is on and not tripping. I found hard start reading 0.0mfd. I replace capacitor and hard start and the compressor still failed to start. No charge for parts, used as a diagnostic. I explained compressor has failed & explained repair/ replacement options.


Jacob M.

Jacob M. Job Checkin

Upon arrival I completed a Full Install of an ive Star 96% Gas Furnace (Up to 100,000 BTU) Honeywell T6 Programmable Thermostat/Emerson 1F85U Five Star 16 SEER Air Conditioner (Up to 3 ton). The system is fully operational upon departure.

Upon arrival I completed a Full Install of an ive Star 96% Gas Furnace (Up to 100,000 BTU) Honeywell T6 Programmable Thermostat/Emerson 1F85U Five Star 16 SEER Air Conditioner (Up to 3 ton). The system is fully operational upon departure.

Shane C.

Shane C. Job Checkin

I completed diagnostics and found the filter plugged. I removed but there was not another filter on site. A 16x25x1 was pulled out of the blower compartment. I recommend a 16x25x4 to add into the filter cabinet. I noticed urine on unit. This can eat away at the coil causing issues and leaking of refrigerant. The system is estimated 3 pounds low on r22 refrigerant. Based on age (18 years old), cost of seen and unseen repairs, having the outdated refrigerant, condition, lack of efficiency and not having a warranty I recommend replacement of AC. I quoted replacement. The homeowners purchased new AC, paid in full. 137341

I completed diagnostics and found the filter plugged. I removed but there was not another filter on site. A 16x25x1 was pulled out of the blower compartment.  I recommend a 16x25x4 to add into the filter cabinet. I noticed urine on unit. This can eat away at the coil causing issues and leaking of refrigerant. The system is estimated 3 pounds low on r22 refrigerant. Based on age (18 years old), cost of seen and unseen repairs, having the outdated refrigerant, condition, lack of efficiency and not having a warranty I recommend replacement of AC.
I quoted replacement. The homeowners purchased new AC, paid in full.

137341

Jacob M.

Jacob M. Job Checkin

Upon arrival the customer stated the system will run for about ten minutes and shut off. A/c has not ran in over a year. I called for cooling and the condenser contactor is not pulling in per the system is low on R-22. I explained repair/ replacement options with customer. The customer needs time to decide decision and will call back.


Jacob M.

Jacob M. Job Checkin

I completed the diagnostics and found the condenser fan motor not running. I discovered the capacitor failed. I explained repair/ replace options and the customer opted to replace. I replaced the cap and charged for it today for cooling until install. I also discounted price of part off of install. The system is operational upon departure.


Jacob M.

Jacob M. Job Checkin

I gave the customer an estimate to run / replace pvc line and leak.


Robby D.

Robby D. Job Checkin

I installed a Five Star 13 SEER 2 Ton Air Conditioner/Carrier 96% 40,000 BTU Gas Furnace; They didn't need a thermostat. This system was operational at the time of departure. With this install comes a scheduled maintenance agreement lasting a year.

I installed a Five Star 13 SEER 2 Ton Air Conditioner/Carrier 96% 40,000 BTU Gas Furnace; They didn't need a thermostat. This system was  operational at the time of departure. With this install comes a scheduled maintenance agreement lasting a year.

Tara L.

Tara L. Job Checkin

I replaced the pressure switch. I cycled the system to ensure functionality. System is operational upon departure.

I replaced the pressure switch. I cycled the system to ensure functionality. System is operational upon departure.

Jacob M.

Jacob M. Job Checkin

Upon inspection, I found the flame sensor was dirty and did not have a secure connection. I cleaned it and reattached the part so that it had a secure connection. I cycled the system multiple times to ensure everything was working. System is operational upon departure.

Upon inspection, I found the flame sensor was dirty and did not have a secure connection. I cleaned it and reattached the part so that it had a secure connection. I cycled the system multiple times to ensure everything was working. System is operational upon departure.

Jacob M.

Jacob M. Job Checkin

I replaced the inducer motor and found the ignitor needs replaced as well. I quoted the part to the customer and will wait for them to touch base with us to order. System is not operational upon departure.

I replaced the inducer motor and found the ignitor needs replaced as well. I quoted the part to the customer and will wait for them to touch base with us to order. System is not operational upon departure.

Jacob M.

Jacob M. Job Checkin

I found the inducer motor had seized. Customer has approved replacement and I will come back out to install once part comes in.

I found the inducer motor had seized. Customer has approved replacement and I will come back out to install once part comes in.

Jacob M.

Jacob M. Job Checkin

I performed a diagnostic on a Lennox gas furnace that is not turning on. I recommended the customer replace the main circuit control board and the pressure switch.

I performed a diagnostic on a Lennox gas furnace that is not turning on. I recommended the customer replace the main circuit control board and the pressure switch.

Jacob M.

Jacob M. Job Checkin

I performed a diagnostic on a Lennox gas furnace that is not turning on. I recommended the customer replace the main circuit control board and the pressure switch.

I performed a diagnostic on a Lennox gas furnace that is not turning on. I recommended the customer replace the main circuit control board and the pressure switch.

Jacob M.

Jacob M. Job Checkin

I performed a diagnostic on a Trane 80% gas furnace. Customer had system off on arrival. Per customer stating furnace giving more than one code, I cycled system. I found system main control board giving intermittent codes/ failed. I explained repair/ replace options. Customer decided to replace

I performed a diagnostic on a Trane 80% gas furnace. Customer had system off on arrival. Per customer stating furnace giving more than one code, I cycled system. I  found system main control board giving intermittent codes/ failed. I explained repair/ replace options. Customer decided to replace