Shawn H.

Shawn H. Job Checkin

Arrived at customers residence and was greeted by the customer and was led to the thermostat and it is functioning properly at this time. Inspected 20x 20x1 and 16x20x1 and they clean at this time. inspected disconnect on side of bracket and it is tighten neat and functioning properly at this time and the securely fasten to bracket. Inspected tape and ductwork joint and they are tight and neat without any visible defects or air leaks at this time. Refrigerant lines are tight and neat and Arma flex insulation Tight and neat and without any visible defects or issues at this time. Inspected evaporator coil and it is clean at this time. Electrical connections or tighten need to the components and Why are not connections are tight and neat without any visible defects at this time. Inspected easy trap safety switch and it is functioning properly. Flush to easy trap. Safety switch and condensation drain At this time. Air handler is sitting level attached to wood bracing that is securely f


Robert  L.

Robert L. Job Checkin

any day but Thursday for install


Loving Air Inc. .

Loving Air Inc. . Job Checkin


Shawn H.

Shawn H. Job Checkin

Arrived at customers residence and was greeted by customer and proceeded to the thermostat and shut off system to proceed outside to out door unit to replace temperature sensor and after replacing sensor started up system to ensure that system and thermostat are cycling properly at this time. Have cycled system twice at this time and system is functioning properly at this time. Inspected condensate drain and it is clear at this time. Condensate pump is functioning properly at this time. Inspected 20x25x1 pleated filter and it is clean at this time. Inspected barometric damper and it is functioning properly at this time. Inspected emergency shut off switch is functioning properly at this time. Upon departure system is functioning properly at this time.


Shawn H.

Shawn H. Job Checkin

Arrived at customers residence and was greeted by customer and was led to the thermostat and it is heat mode and is functioning properly at this time. Inspected outdoor temperature sensor and was unable to properly ohm sensor due to not having charge to properly find if ohms are correct or not. Found wiring on thermostat to be heavily bald up causing thermostat not to make normal connection due to bulging and the wire section of the thermostat. Inspected low-voltage wiring on Beckett burner found back up burner is functioning properly and low-voltage wiring is in proper condition, no shorts marred or breaks at this time. Inspected outdoor unit heat pump, system wiring and found no evidence of being wired wrong at this time. Office will need to order new outdoor temperature sensor was unable to make order due to after hours at this time. Yes. I want to do forget them. Upon departure system is running normally at this time. Customer stated that he is surprised that system is still runn


Elgin P.

Elgin P. Job Checkin

installed new mini split started and tested all functions of the system everthing working within manufacturers specs


Mike  M.

Mike M. Job Checkin

Arrived to the customer home and greeted her at the front door. Spoke with the customer about reason for wanting her fire place serviced. Customer led me to the fire place. Began the maintenance of the fire place by removing all wood and cleaning all dust and debris from them and set them aside. Using a brush and vacuum cleaned all debris from inside the cabinet and front. Confirmed gas line and valve were in good condition and working properly. Replaced customer provided AAA battery to allow the spark ignition to work properly. Reinstalled all wood and fired off fireplace and running for several 10 minutes with no concerns found. Found no data plate or sticker to log equipment in notes. Uploaded pics and video from today’s maintenance. Spoke with customer about having an inspection done on her hvac equipment and was told already has another company that services them but doesn’t work on fireplaces. Collected payment and returned system to service


James M.

James M. Job Checkin

Upon arrival spoke with customer. Went to stat and stat was set correct. Went to crawl and indoor is working properly. Went outside and found capacitor bad. Got customer approved and replace capacitor. Started system and tested all functions of system. It is working well at this time.


Shawn H.

Shawn H. Job Checkin

Arrived at customers residence and walked around to the back of the property and found the package unit .. Set thermostat to emergency heat mode and and inspected heater kit and it is operational at this time with an amp draw of 39.2 amps at this time… Inspection blower wheel and coil both are lightly dirty at this time.. Inspected dual disconnects and both are are tight and neat to the outside of the home at this time.. Inspected all electrical connections and all are tight to their components at this time.. Also inspected wire nut and they are also tight and neat at this time.. Condensate pan is dry and clean at this time…. Also thermostat is also operating normally according to manufacturers specifications at this time. Inspected contactor and it has 238.8 volts coming in and the same coming out at this time…inspected fan motor and blade both are clean and operational at this time..Fan motor has an amp draw of 1.6 amps.. Unit is sitting level on bricks. Also inspected 14x24x1 filt


James M.

James M. Job Checkin

<br> Upon arrival spoke with customer and stat was not working. No 24v. Went to crawl, found fuse blown. Put fuse in and tested all the wires and nothing was tripping. Indoor is clean, went to outdoor unit, wires all tight. Found high pressure switch wire was rubbing copper. Fixed wire. Tested system and system is working great at this time of service.


Dakota H.

Dakota H. Job Checkin


Cameron S.

Cameron S. Job Checkin

. Upon arrival found system running. Customer said the last couple days it hasn’t been running at all. Turned the thermostat off. Went to indoor unit. The indoor blower was still running. Had no call for the blower from the thermostat. Turned the system to ac. The unit would come on amd then cut off and then came back on again. Found indoor control board going bad. Called mod. Explained to customer that putting a bunch of money into a older system in this condition isn’t the best option. Called mod to quote customer opinions. Mod is set to come out Monday 9-11.


Cameron S.

Cameron S. Job Checkin

. Upon arrival turned the system to ac. Went to indoor unit. The 10uf capacitor was very rusted. Showed the customer. The blower is clean. The blower motor amped within the manufacture specifications. The coil is clean. The coil is a little rusted but no leaks at this time. Inspected low and high voltage wiring. All wiring is good and tight. The drain is clear. Went to outdoor unit. The 40/5 capacitor was weak. Quoted to replace it and the 10uf. Customer approved. Installed new 40/5 and 10. Started system. The compressor amped at 6.01. The condenser fan motor amped at .64. Both are within the range per manufacture specifications. The Refrigerant pressures were 65/175. 10 Subcooling. No signs of leaks. The system is now working properly. Signed the customer up for membership.


James M.

James M. Job Checkin

Upon arrival tested system, blower is dirty, coil is clean, no leaks. Drain line is clear but has adhesive around the drain pan where it meets the drain line. Turned ac on, blower came on, amped at 1.4amps. Compressor amped at 4.5amps. Outdoor fan amped at 1.3amps. Refrigerant levels are sealed in system but it has a 15° split at this time. System is working properly. Turned power off to system and disconnected system completely. Put system outside and covered it with a tarp. Need 1, 12inch 90° for the return when we come back. Spoke to customer on the phone when I first arrived and explained I would call with a price and she told me just to get it done she was not worried about that. Quoted 8hours(4 today, 4 to reset unit). Pull unit and re install unit, need 12 inch 90. Customer is selling home, will need extra help putting unit back


Jeremy S.

Jeremy S. Job Checkin

Airhandler. The blower amps are 1.4 in correct range per manufacturer specifications. The evaporator coil is clean and free of debris. The emergency heat amps are 20.21/20.4 in correct range per manufacturer specifications. The condensate drain is clear and flowing freely. I recommend an ez trap for the system. The wiring is tight and free of damage. The system is working properly at this time. Heat pump. The compressor amps are 5.89 in correct range per manufacturer specifications. The condenser coil is clean and free of debris. The condenser fan amps are .6 in correct range per manufacturer specifications. The run capacitor is in correct range per manufacturer specifications. The 1 pole contactor is in good condition. The refrigerant pressures are 440/140 in correct range per manufacturer specifications. The wiring is tight and free of damage. Defrost is working properly at this time. The system is working properly at this time. The customer declined recommendations at this t