On time, knowledgeable, polite

Shawn is an excellent tech. He explains what he’s doing and why. He also advises if he sees something that should be taken care of.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very personable and informative! Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service! Punctual, friendly and professional.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for montross, va

Shawn H.

Shawn H. Job Checkin

Arrived at customers residence and was greeted by the customer and was led not the inside wall units and they are all level and and secure to the walls . Inspected wireless remotes and they are functioning pro-perky at this time. Inspected washable filters and they are all clean at this time. Leuvers on units are functioning properly at this time.Inspected blower motor and wheels on wall units and they are all clean and functioning properly at this time. Inspected evaporator coils and they are clean at this time inspected. Insensate drains and they are clean and clear at this time. Inspected communication lines and they are tight and neat to the units at this time. All wireless remote thermostats are functioning properly at this time. Inspected outdoor disconnect and it is functioning properly and is tight and neat to the side of the home ant this time. Refrigerant lines are tight and neat and insulation is and it is clean at this time.intact and without any visible defects at this t


Shawn H.

Shawn H. Job Checkin

Arrived at customers residence and was greeted by customer and was led to the outdoor mini split condenser. inspected condenser coil and found that it was dirty when I had an applied crud buster to clean condenser coil and fan blade at this time. Inspected Condenser, converter board is clean and functioning properly at this time. Inspected outdoor disconnect and it is take me to the side of the home at this time. Outdoor unit is sitting level on pad at this time. Inspected first line hide cover it’s nice and tight to the side of the home. Found no defects at this time. Expected line hide cover for two through four and they are tight and neat to the side of the home at this time. all refrigerant lines are tight and neat to the condenser and Arma flex insulation is intact on all four lead lines out of the house into the condenser and without any visible signs of defects, breaks, or tears at this time.. condensate drains are clear at this time, and without any visible obstructions at th


Shawn H.

Shawn H. Job Checkin

Arrived at customers residence and was greeted by customer and led to the system for post install inspection.. inspected heater kit and it is clean has an Abgrall coming in of 20.5. Inspected blower motor and wheel and it is clean and also inspected evaporator coil and it is clean at this time. Blower motor amp draw is .8.inspected all tape joints and duct work joints are tight and neat at this time. All electrical connections are tight and neat to the components and wire nut connections are tight at this time. Inspected condensate drain and found it to be clean at this time… Inspected condensate drain and it is clear at this time.. inspected refrigerant lines and they are tight and Armor cell insulation is intact and without any rips tears and defects at this time… engaged and disengaged 60 amp circuit breaker and it is working according to manufacturers specifications at this time. Inspected 8448 Aprilaire thermostat and it is operating normally at this time. Compressor amp dr


Shawn H.

Shawn H. Job Checkin

Arrived at customers home and was greeted at the residence. Customer directed me to the thermostat to put it in heat mode.. approached attic hatch in garage are and was unable to gain access into attic due to personal belongings in the way.. Also very small access area, would require small slim technician to gain access. Inspected heat pump disconnect and it is tight to the house and sealed… inspected refrigerant lines and they are neat and tight.. Armor cell insulation is intact and without rips and tears at this time.. Inspected contactor volts coming in is 242.8. And going out is 243.0 volts. Inspected fan motor and blade and found that fan motor has rust showing on motor housing but found no leaks from seals at this time. Inspected capacitor and it is in range at this time.. inspected condenser coil and found it to be clean overall. Inspected 20 x 25 by one filter found it to be dirty and replaced it with a customer purchase 20 x 25 by one filter. Overall system is operating no


Loving Air Inc. .

Loving Air Inc. . Job Checkin

Installed new attic system everything working properly


Dakota H.

Dakota H. Job Checkin


Trey M.

Trey M. Job Checkin

During my inspection the customer greeted me at the door and proceeded to tell me the system was off completely by the breaker. After cutting those on the customer explained to me the air coming out of the vents in the attic was contaminated with black specs. She was worried about a fire hazard. She also explained that there was no cold air coming out of the system. Upon further inspection of the system I found that the indoor unit was extremely dirty and the blower wheel was extremely impacted by dust, dirt, debris. As well as the indoor coil. This was causing the black flakes that were coming out of the system. The amp drawls for the indoor blower motor or within spec at .52 A. I then made my way to the outdoor unit where I started by checking power coming into the unit. I did have 240 V. When the unit went to start up I noticed that the compressor was short cycling. I’ve been checked the capacitor and found that the 35/3 UF capacitor was low only reading 28/2.9. I then opened u


Ryan G.

Ryan G. Job Checkin

Arrived at home knocked on the door, customer and greeted us at the door we asked to see the indoor thermostat indoor unit. Customer granted access to thermostats but decline access to indoor unit at this time. Could not check due to not being allowed into the attic. Told customer that we would check outdoor unit and will be back in with our findings. Turn system in cooling to properly checked charge. Check system charge but due to previously stated ductwork issue systems charge is in accurate. Took amp draw on compressor of 5.7 which is in range per manufacture specs. Took amp draw of outdoor fan motor of .5 which is in range per manufacture specs. Checked 40/5 capacitor got a reading of 39.1/4.4 which is under manufacture specs will recommend replacing. Checked contactor and is in good shape at this time. Check fuses on 60 amp disconnect and are in good shape at this time. Checked all high and low-voltage wiring on outdoor unit in are in good shape at this time. Due to customers mem


Jeremy S.

Jeremy S. Job Checkin

The heat pump is not running. I found the 45/5 run capacitor bad. The standing refrigerant pressures are a little low. I completed a complimentary refrigerant leak search on the system. I found leaks in the condenser coil and evaporator coil. I called the manager on duty per company policy for a verification visit. Rick is on his way to the customers house. I called trane for parts availability and pricing. The condenser coil is obsolete and not available anymore. The compressor Megohmmed green (good). Rick arrived and is going over options with the customer.


Jeremy S.

Jeremy S. Job Checkin

The customer requested checking only the outdoor. The condenser coil is clean and free of debris. The condenser fan amps are .37 in correct range per manufacturer specifications. The run capacitor is in correct range per manufacturer specifications. The compressor amps are 6.49 in correct range per manufacturer specifications. The contactor is in good condition. All wiring is tight and free of damage. The defrost cycle is working properly at this time. The refrigerant pressures are 370/130 in correct range per manufacturer specifications. The system is working properly at this time. The customer requested a paper copy of today’s visit.


Jeremy S.

Jeremy S. Job Checkin

The customer requested to inspect only the outdoor unit. Heat pump. The condenser coil is clean and free of debris. The 40/5 run capacitor is weak on the herm and fan. The condenser fan amps are .29 in correct range per manufacturer specifications. The compressor amps are 6.72 in correct range per manufacturer specifications. The contactor is in good condition. The refrigerant pressures are 280/135 off a little due to rain but in correct range per manufacturer specifications. The wiring is tight and free of damage. The system is working properly at this time. I received permission for repairs. I replaced the 40/5 run capacitor. The customer signed up for our basic one system Club Membership. The customer requests a paper copy of today’s invoice.


Cameron S.

Cameron S. Job Checkin

Cooling inspection 2 systems on main house Attic indoor Inspected evap coil and blower wheel both clean and free of debris, inspected blower amps .80 in range per manufacturer specs, inspected electrical wiring and connections none found burned are broken at this time, inspected condensation drain blow out and tested all working good at this time, inspected duct work all in tact working good at this time, inspected filters all clean when we were here, inspected and tested t-stat operations all working good at this time, Attic heat pump Inspected condensation coil it was clean rinsed off with just water, inspected electrical wiring and connections none found burned are broken at this time, inspected contactor no pitting are arc marks at this time, inspected capacitor it was in range per manufacturer specs, inspected compressor amps 8.67 in range per manufacturer specs, inspected outdoor fan amps .90 in range per manufacturer specs, inspected charge on system was perfect 7 deg