Wonderful service.

Dedicated personnel. Gave detailed explanations.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Professional service, as usual.


Response from Loving Air, Inc.:

Paul, Thank you for the 5 star review. We appreciate you taking the time to let us know that we are providing a professional service. Let us know if there is anything else we can do for you. Have a great day.

  • Overall Experience
  • Quality
  • Price
  • Convenience

did a great job getting unit running again


Response from Loving Air, Inc.:

Peggy, Thank you for a great review. Please let us know if there is anything else we can do. Have great day. Shane Loving

  • Overall Experience
  • Quality
  • Price
  • Convenience

great service

very nice and polite to all of us at the stanley home


Response from Loving Air, Inc.:

Thank you for the wonderful review. Please let us know if there is anything ese we can do for you. Have a great day. Shane Loving

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for sperryville, va

Shawn H.

Shawn H. Job Checkin

Arrived at customers residence and was greeted by customer and was led to the thermostat and it is functioning properly at this time. Inspected 16x20x1 filter and it is clean at this time. Also replaced cover on filter and showed customer how it fits at this time. Airhandler is sitting level on kindorf bracket at this time and is attached to floor joists at this time. Tape and duct work joints are tight and neat at this time and without any visible defects or air leaks at this time. Refrigerant lines are tight and neat and Arma flex insulation is intact and without any visible defects at this time. Inspected ez trap safety switch and it Is functioning properly at this time. Inspected CS1 safety switch and it is functioning properly at this time. Inspected 2- 60 amp circuit breakers they are functioning properly at this time. Inspected evaporator coil and it is clean at this time. Inspected blower motor and wheel and they are functioning properly Fan motor seals are tight and without


Loving Air Inc. .

Loving Air Inc. . Job Checkin

Arrived at the home customer greeted me at the front door in allowed me inside. Asked to see where the thermostats were located and where to find all three indoor units. I started with the carrier main house basement system. Basement carrier furnace Turn the fan in the on position, I took an amp draw of indoor fan motor of .8 which is in range per manufacture specs. Indoor blower wheel was a little dirty along with indoor evaporator coil being a little dirty due to customers membership was able to remove dirt with brush. Leak search evaporator coil did not find any leaks at this time. Checked all high and low voltage wiring and are in good shape at this time. Checked condensate drain did not find any leaks at this time. Notice customer did not have easy trap drain will recommend installing one. Basement train furnace Took an amp draw of indoor blower motor of 2.8 which is in range per manufacture specs. Checked evaporator coil and blower wheel both are clean and free of debris a


chrisw@lovingairinc.com

chrisw@lovingairinc.com Job Checkin

Arrived to make recommended repairs. Removed blower assembly for the second floor system and cleaned the assembly. Reinstalled blower assembly and checked operation. Blower is operating properly and amping within range. Also cleaned the evaporator coil for the upstairs system. Both the coil and blower assembly are now clean. Replaced (2) 35/5 dual run capacitors. First capacitor is for the upstairs system and second for the main floor system. Cycled both on after replacing the capacitors, both are running and operating properly. Compressors and condenser fans are amping within range of manufacture specifications. Systems are operating properly at this time.


chrisw@lovingairinc.com

chrisw@lovingairinc.com Job Checkin

Performed heating maintenance on three systems. Main house basement system, Inspected blower assembly and evaporator coil for cleanliness, blower assembly is ok, evaporator coil is dirty and recommend cleaning. Inducer motor is amping within range of manufacture specifications at 0.5. Blower motor is amping at 6.1 which is also within range of manufacture specs. All wire connections are tight with no broken or frayed wires. Burners are ok with no debris build up. Flue is intact and has correct grade. Gas pressure is correct for high and low fire (LP). Heat exchanger has slight rust around burners but no cracks or holes found. Cleared all pressure switch tubes. Recommend adding an eztrap to the drain to help prevent any condensation related issues in the future. Condenser coil is clean and free of debris. Condenser fan motor is amping at 0.5, which is within range of manufacture specifications. Compressor is amping at 4.8 which is also within range of manufacture specifications. All w


Cameron S.

Cameron S. Job Checkin

. Upon arrival found tstat bad. Put customers tstat on. Found that also bad. Put one from my truck on and everything worked properly. Signed customer up for membership.


Ryan G.

Ryan G. Job Checkin

Cooling inspection three system Attic indoor Inspected blower wheel and evap coil both clean at this time and working well, evap coil is very rusted performed leak search no leaks found at this time, inspected blower amps 1.2 in range per manufacturer specs, inspected electrical wiring and connections none found burned are broken at this time, inspected condensation drain blow out and tested also went outside used shop vac to clear drain all is good at this time, inspected emergency pan safety switch tested it worked great at this time. Inspected duct work all intact working well at this time. Inspected filters both filters where dirty pulled them homeowner will replace with new ones indoor is performing well at this time. Attic heat pump Inspected condenser coil it is clean at this time, rinsed off with water only, inspected compressor amps 5.56 in range per manufacturer specs, inspected outdoor fan amps .60 in range per manufacturer specs, inspected contactor in good shape


Lee S.

Lee S. Job Checkin

Replaced defrost control board and ck operation rts!


Lee S.

Lee S. Job Checkin

Ck system to find defrost control board is not feeding common on control wire through defrost control board. Jumped out for now to get homeowners cooling. To be installed 7/13/21 8-10 am


James M.

James M. Job Checkin

Upon arrival shut power off to the unit and replaced fan motor and capacitor. While fan motor was out I cleaned the coil and got the debris out of inside the unit. Put everything back together and started the unit. Let unit for for alittle bit, charge looked ok, when turning unit off, you could hear the blade slip just slightly. Explained to customer with its age and everything the blade could be warring out and causing a slight noise as well. I told him to keep an eye on it and if it gets worse we can price it up to replace the blade. Customer is very happy with the service at this time.