We are very happy to have hot water but would like it to be hotter thank you Carmine and Lucy please give us a call
my only dissatisfaction is that I thought since I became a club member I would receive the 15% off of this bill the first gentleman who came out said I would receive it and he told me it would be $1500 so what happened to my $150.00 discount ! my bill should have been $1350
very good job done by Norbey, he is very polite and very "professional" highly recommended,I am pleased with results ...
Removed old pressure assist toilet not working properly and install new Gerber Viper with new toilet seat, set it on grout replacing wax seal, Jonny bolts and flex supply. Shut off water main and install new quarter turn angle stop for toilet.
Al had a hose bib near his pool which was leaking quite a bit. I could not see how it was attached to the pipe so I had to cut the wall a bit to reveal a solder joint. I had to remove the compressed fiberglass siding to unswept the old hose bib off. Resoldered a 2" extension and new 1/2" Qt brass hose bib and tested. Everything is working great now with no issues or leaks. Al will be replacing the siding himself.
Al had a hose bib near his pool which was leaking quite a bit. I could not see how it was attached to the pipe so I had to cut the wall a bit to reveal a solder joint. I had to remove the compressed fiberglass siding to unswept the old hose bib off. Resoldered a 2" extension and new 1/2" Qt brass hose bib and tested. Everything is working great now with no issues or leaks. Al will be replacing the siding himself.
Al had a hose bib near his pool which was leaking quite a bit. I could not see how it was attached to the pipe so I had to cut the wall a bit to reveal a solder joint. I had to remove the compressed fiberglass siding to unswept the old hose bib off. Resoldered a 2" extension and new 1/2" Qt brass hose bib and tested. Everything is working great now with no issues or leaks. Al will be replacing the siding himself.
Al had a hose bib near his pool which was leaking quite a bit. I could not see how it was attached to the pipe so I had to cut the wall a bit to reveal a solder joint. I had to remove the compressed fiberglass siding to unswept the old hose bib off. Resoldered a 2" extension and new 1/2" Qt brass hose bib and tested. Everything is working great now with no issues or leaks. Al will be replacing the siding himself.
Found a leaky water heater on bottom element and thermostat. Tank was 14 years old. Suggested replacement. Install new 40 gallon Bradford white water hater with new expansion tank, new ball valve, new drop pan and new disconnect switch on the wall. Water heater located on second floor closet. M# RE34016. S#NE37752417
Replacing defective disconnect for condenser, removed defective disconnect, installed new disconnect with 60 amp breaker, turned on power, tested and started unit, all operations normal at this time.
Check on toilet in master bathroom, fill valve getting stock. Also, water valve drips. Shut off water main, install new angle stop and flex supply, new fluid master fill valve and adjusted water level. Flush toilet several times, working properly.
Don and I high pressure jetted Jose's sewer after locating and excavating buried cleanout on front of house. I raised up the PVC cleanout 6" above grade in the landscaping area. We also camera inspected sewer line from cleanout to guest toilet and from cleanout to main sewer in street. All the sand and debris has been removed and the pipe is in great shape. Reset the guest bathroom toilet and tested all work. Everything is functioning as designed with no issues or leaks.
Don and I high pressure jetted Jose's sewer after locating and excavating buried cleanout on front of house. I raised up the PVC cleanout 6" above grade in the landscaping area. We also camera inspected sewer line from cleanout to guest toilet and from cleanout to main sewer in street. All the sand and debris has been removed and the pipe is in great shape. Reset the guest bathroom toilet and tested all work. Everything is functioning as designed with no issues or leaks.
Don and I high pressure jetted Jose's sewer after locating and excavating buried cleanout on front of house. I raised up the PVC cleanout 6" above grade in the landscaping area. We also camera inspected sewer line from cleanout to guest toilet and from cleanout to main sewer in street. All the sand and debris has been removed and the pipe is in great shape. Reset the guest bathroom toilet and tested all work. Everything is functioning as designed with no issues or leaks.
Don and I high pressure jetted Jose's sewer after locating and excavating buried cleanout on front of house. I raised up the PVC cleanout 6" above grade in the landscaping area. We also camera inspected sewer line from cleanout to guest toilet and from cleanout to main sewer in street. All the sand and debris has been removed and the pipe is in great shape. Reset the guest bathroom toilet and tested all work. Everything is functioning as designed with no issues or leaks.
Installation of a new main shut off valve and two new hose bibbs, turn on water and check operation, all working properly.
Complete installation of a new 50 gallon natural gas Bradford White water heater.
Replacing main shut off valve in unit under air handler accessing from closet on back side by cutting wall and installing 8" by 8" access panel. Maintance person turned building water off and on