1638 Elkton Road
Elkton, MD 21921
410-392-9350

Local Reviews
for clayton, de

Rated 5.0 out of 5 stars based on 2 customer reviews

Outstanding service

Jack was very friendly and offered tips on how to keep our system running in good order.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Service was perfect.

Arrived in time and preformed the service quickly.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for clayton, de

Tammy A.

Tammy A. Job Checkin

WO-TNFR246287


Clay K.

Clay K. Job Checkin

Damage from storm, outdoor system has been knocked down, see photos, both service valves need to be replaced.


Greg H.

Greg H. Job Checkin

Found leak at tankless water coil not related to emailed over estimate left a voice mail for callback


kozemchakmoonservices@gmail.com

kozemchakmoonservices@gmail.com Job Checkin

Upon arrival found leaking pipe connection on downstairs (Music Room) copper water line. We will return and do all repairs at once for the boiler and the pipe connection.


Clay K.

Clay K. Job Checkin

Small condensate leak at the head unit, tube insulation loose, repair and test with water.


Jack W.

Jack W. Job Checkin

Look at first invoice


Jack W.

Jack W. Job Checkin

Mini split cleaning: cleaned off all air filter systems on each head unit. All air movement systems were clean and clear of all debris and signs of concern. Checked all wiring which were clean and secure. Outdoor wiring looked clean and secure. Cleaned off inside and outside of outdoor unit. System was up and running at normal operation at the end of the visit.


Kyle H.

Kyle H. Job Checkin

Cleaned all filter all evaporator coils are clean. Housings are clean getting Appropriate heat rises. Checked units for error codes. condenser coil is clean. Eletracal connections are tight Checked outside units operation normal at this time.


Greg H.

Greg H. Job Checkin

Replaced condesate pump test ran operation normal at this time ol


Mike R.

Mike R. Job Checkin

Checked air conditioning system. Found system opererating properly upon arrival. 130/290. Sh 11, SC 9. 18o delta t. Advised customer system requires yearly maintenance.air filter clean. Condensate clear.


Craig D.

Craig D. Job Checkin

Heating Rejuvenation Heating supply 140, 15 psi of water. Flue pipe structurally sound, no soot. No smoke coming out of flue. No water leaks. Cleaned cad cell. Changed nozzle, strainer and oil filter. Bled air out of system and test ran boiler. System normal operation at this.


Craig D.

Craig D. Job Checkin

Heating Rejuvenation Heating supply 140, 15 psi of water. Flue pipe structurally sound, no soot. No smoke coming out of flue. No water leaks. Cleaned cad cell. Changed nozzle, strainer and oil filter. Bled air out of system and test ran boiler. System normal operation at this.


Craig D.

Craig D. Job Checkin

Heating Rejuvenation Heating supply 140, 15 psi of water. Flue pipe structurally sound, no soot. No smoke coming out of flue. No water leaks. Cleaned cad cell. Changed nozzle, strainer and oil filter. Bled air out of system and test ran boiler. System normal operation at this.


Craig D.

Craig D. Job Checkin

Heating Rejuvenation Heating supply 140, 15 psi of water. Flue pipe structurally sound, no soot. No smoke coming out of flue. No water leaks. Cleaned cad cell. Changed nozzle, strainer and oil filter. Bled air out of system and test ran boiler. System normal operation at this.


Tyler C.

Tyler C. Job Checkin

On first level of house Short line set New Return box with possible duct board modification