1638 Elkton Road
Elkton, MD 21921
410-392-9350

Local Reviews
for bel air, md

Rated 4.8 out of 5 stars based on 6 customer reviews

Great

He was a grate person to hav

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Clay was very professional, took his time, and determined the problem and solution.

  • Overall Experience
  • Quality
  • Price
  • Convenience

explanation of services great

  • Overall Experience
  • Quality
  • Price
  • Convenience

Quality service, dependable

Moon always keeps us updated with maintenance service visits. Service personnel are very professional and explain what they did to service the equipment.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very courteous and professional


Response from Moon Air Inc.:

We are so grateful for your great review. Thanks for sharing your rating with us and the community.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service!

Craig arrived and replaced our failed air condition at one of our remote equipment sites quickly and efficiently. We were able to get our space cooled quickly, which helped to prevent our equipment from overheating.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for bel air, md

howardmjr22@gmail.com

howardmjr22@gmail.com Job Checkin

Performed club AC cleaning rejuvenation. Heat transfer media coil system is clean no leaks. Air movement system has Variable speed motor. Air movement blower wheel is clean. Flushed out drain and trap. Checked safety is good operating as intended. Checked all electrical wiring connectors and harness are tight and secured. Air filter is clean 16X25X1 Delta T 21 degrees. Outdoor air movement system factory specs 1.7amps actual 1.30amps refrigerant pumping system RLA 17.9amps actual 6.50amps. Voltage enhancement system factory specs 45/10 actual 42/9 recommend replacing, voltage gateway is good res of 18.9, cleaned condenser coil wiped unit down with WD40


Steven P.

Steven P. Job Checkin

19"roof jack from top of furnace to inside ceiling 75.25" furnace and coil box


howardmjr22@gmail.com

howardmjr22@gmail.com Job Checkin

Found faulty air movement system and combustion removal system needs to be replaced


Josiah  S.

Josiah S. Job Checkin

WO-TNFR240163


Clay K.

Clay K. Job Checkin

No heat, air handler with wet coil, not closed due to screws missing on cover, customer removed to change the indoor air filter.


Tammy A.

Tammy A. Job Checkin

bought filters


Kyle H.

Kyle H. Job Checkin

Club rejuvenation furnace cleaning inspected gas line supply to valve, inspected exhausted and fresh air make-up. Inducer motor is within specs 2.14amps heat exchanger is clean no signs of rust or cracks, 16X25X1 media air filter is within recommendation to be replaced. April aire humidifier filter is clean. Solinoid for humidifier is working as intended. All electrical wiring connectors and harness are tight and secured. Supply air temp 122 degrees return air temp 81 degrees Delta T 41 degree differential. Condensate drain is clean and flowing


Amanda S.

Amanda S. Job Checkin

Air Conditioning Repair near Irish Rd. Upon receiving a service call for a malfunctioning air conditioning system, our technicians quickly arrived at the customer's residence. After diagnosing the issue, we identified a faulty motor as the cause of the system's failure to start. With precision, we repaired the motor, ensuring the smooth operation of the air conditioning system. The customer was relieved to have their cooling restored and expressed appreciation for our efficient repair services.


Amanda S.

Amanda S. Job Checkin

Indoor Air Quality Solutions near Brooks Rd. A homeowner called us and expressed concerns about airborne pathogens and allergens circulating in their home. After a comprehensive evaluation, we recommended the installation of a UV light system within the air conditioning unit. The UV light effectively neutralizes bacteria, viruses, and mold spores, improving indoor air quality. The homeowner was delighted to have a cleaner and healthier living environment.


Paul N.

Paul N. Job Checkin

WO-TNFR156760 Performed basic air exhaust removal system renovation. Checked operation.


Jack W.

Jack W. Job Checkin

AC inspection: delta T was 19. Air filter system was clean and clear of all debris. Air movement system was dirty and rusted so I'm giving the customer an estimate on replacing that. All wiring was clean and secure. Drain line system was clean and clear. Evap coil was dirty so I'm giving the customer an estimate on cleaning that. Voltage enhancement system was running at 29.8/4.9uf. factory spec is a 30/5uf. Voltage gateway system was clean and clear of all the debris and signs of concern or worry. Outdoor system was dirty so I'm giving customer an estimate on cleaning that. System was up and running at normal operation at the end of the visit.


Jack W.

Jack W. Job Checkin

Ac club rejuvenation: the supply temperature was 39 degrees and the return temperature was 68 degrees. The delta T had a temperature difference of 29 degrees. Checked air filter system, which was clean and clear of all debris because customer changes out. Checked air movement system, which was clean and clear of all debris with no signs of concern or worry. Checked all wiring inside electrical compartment, which were all clean and secure. Checked drain line system, which was clean and clear of all debris with no signs of concern. Cleaned inside and outside of indoor unit with proper cleaner and wipes. Checked outdoor voltage enhancement system, which was running at a 44.8/9.9uf. Factory spec is a 45/10uf so it was running within the allowable fault of the system. Checked outdoor voltage gateway system, which was clean and clear of all debris with no signs of concern or worry. Cleaned off inside and outside of outdoor unit with proper cleaner and wipes. System is up and running at norma


Matthew  F.

Matthew F. Job Checkin

Club ac rejuvenation, Supply has a temperature of 42 degrees. Return has a temperature of 63 degrees. Delta t of 21 degrees. All indoor control board connections are good. Air filter is clean. Checked evaporator coil and pan both are clean and looking good. Cleaned out ez trap with the provided brush. Wd40 wipe down of the indoor unit. Outdoor voltage enhancement system is reading 43.5/9.8uf and with a factory spec of 45/10uf it is within the allowable fault. The electrical gateway is without any pitting or burn marks and looks good. Cleaned off outdoor coil as well as the bottom of the unit to clear out all of the drain holes. Wd40 wipe down of the outdoor unit. System is operating normally at this time.


Keith F.

Keith F. Job Checkin

Will make decission by Monday Feb 21


Craig D.

Craig D. Job Checkin

Heating Rejuvenation Indoor unit supply 132 with a 73 return and 59 heat rise. Static pressure 0.3 (0.3 supply, 0 return). Blower amps 3.7, exhaust system amps 0.3. Flame sensor read 3.4uA. Flames blue no rollbacks. Board and connections fine. Heat exchanger fine. Cleaned blower wheel. Air filter clean. System normal operation at this time.