Greg H.

Greg H. Job Checkin

Oil boiler club service noticed pipe were cold upon arrival found aquastat not always working did club service changed nozzle and filter and gaskets cleaned cad cell tested igniter cleaned heat exchanger operation normal at this time


Paul N.

Paul N. Job Checkin

Checked operation of heat pump/boiler system.


Greg H.

Greg H. Job Checkin

WO-TNFR225091 replaced control system test ran operation normal at this time test ran heat pump operation normal at this timr. while serving hot water heater operation normal at this time.


Greg H.

Greg H. Job Checkin

Did cleaning


Greg H.

Greg H. Job Checkin

WO-TNFR221680 replaced flow sensing system getinng new code control board is starting to fail will need to return


Greg H.

Greg H. Job Checkin

Cleaned all indoor heat transfer systems on mini splits. All indoor air circulation systems were clean. Washed all filters. Checked for error codes and none came up. Cleaned off outdoor unit with degreaser. Found two gas leaks on outdoor fuel line before the regulator Need to call gas company for repairs.


Greg H.

Greg H. Job Checkin

Upon arrival found flow sensing system has failed will need to get pricing tomorrow morning


Greg H.

Greg H. Job Checkin

Changed filters and nozzle and gaskets cleaned cad cell tested ignition system checked heat exchanger and flue pipe operation normal at this time


Tammy A.

Tammy A. Job Checkin

Gold heat pump with complete duct system


Steven P.

Steven P. Job Checkin

Gold heat pump with complete duct system. Begin with demo of existing ductwork on Tuesday 3/28 and return by Friday 3/31 or Monday 4/3 to begin install of new system


Jack W.

Jack W. Job Checkin

Daikin Mini Split Rejuvenation: Checked all head unit filters which were dirty so I cleaned off with water and paper towels. Checked all units air movement systems which were clean and clear of all debris with no signs of concern. Cleaned off outside of each head unit with proper cleaner and brushes. Checked all wiring inside each units electrical compartment which were all clean and secure. Cleaned off outside of outdoor unit with proper cleaner and tools. Each system was up and running at normal operation at the end of the visit.


Mike R.

Mike R. Job Checkin

Completed Heat Rejuvenation. Cleaned boiler and chimney base. Replaced fuel system parts.


Greg H.

Greg H. Job Checkin

Replaced exhaust removal system test ran operation normal at this time.


Mike R.

Mike R. Job Checkin

Cleaned and serviced oil heating hydronic system. Replaced oil filter cartridge, oil burner nozzle. Cleaned heat transfer system and chimney base. Secured exhaust piping with screws. Adjusted high temperature safety system. Removed low limit(heat only application, not needed). Decreased high limit from 175o 170o per customer request. (Recommend it not be lowered further will effect the heating capacity in home in extreme temperatures). Adjusted chimney damper for proper pressure adjustments for equipment. -.04 breach/-.02 overfire. Completed combustion analysis. CO2 12.2 %, excess air 30%, 330o net combustion temperature. 9 ppm CO. 87.3% efficiency. 0 smoke. 15 second safety timing.


Matthew  F.

Matthew F. Job Checkin

Club mini split rejuvenation, cleaned off all of the head units filters. Cleaned off all of the indoor coils with water. All of the indoor electrical connections are secure. Interrogated all head units for error codes, none were found. Wd40 wipe down of all the head units. Cleaned off the outdoor coil. Wd40 wipe down of the outdoor unit. The system is operating normally at this time.