Amanda S.

Amanda S. Job Checkin

Electrical Repair Service: Responding to a homeowner's concern about flickering lights and intermittent power outages, our skilled electricians conducted a thorough inspection of the electrical system. The investigation revealed a damaged circuit breaker and faulty wiring as the primary issues. With precision and expertise, we promptly replaced the faulty breaker and repaired the wiring, ensuring a stable electrical supply. Our comprehensive approach included a detailed examination of other electrical components to prevent potential issues, providing the homeowner with a safe and reliable electrical system.


Blake B.

Blake B. Job Checkin

Club ac rejuvenation, downstairs furnace, 19 delta t, changed filter customer supplied, voltage enhancement system 10 factory is good and in spec, checked all board connections everything is secure and tight, checked blower wheel spins with no restrictions, checked condensate line for blockage and it is fine, no issues. Attic furnace, 15 delta t, voltage enhancement system 7.5 factory still in spec but getting close to needing changed, checked blower wheel spins with no restrictions, checked all board connections everything is secure and tight. No issues. Bedroom filter did not need changed yet as it's still pretty clean. Outdoor unit, voltage enhancement system in spec, cleaned bottom of unit of leaves and rocks, coils look great, checked connections to make sure everything is tight no issues. Outdoor unit voltage enhancement system in spec, cleaned bottom of unit of leaves and rocks, coils look great, checked connections to make sure tight, no issues.


Cameron J.

Cameron J. Job Checkin

The attic furnace supply reads 129 with a return of 78 making our heat rise 51. The voltage enhancement system reads 7.4 with a factory setting of 7.5 fan blower is cleaned and running without any restrictions. Flame sensor and burners are cleaned and looks to be in good condition. All wiring are connected and tightened. Exhaust removal system reads 2.4 FLA at normal state. Changed all 2nd floor filters and replaced them with new filters. Overall attic furnace is running at normal operations at this time The basement furnace supply reads the basement supply reads 122 with a return of 78 making the heat rise 44. Fan blower is cleaned and running without any restrictions. The Voltage enhancement system reads 9.8 with a factory setting of 10 exhaust removal system reads 2.4 FLA that’s is running normal. Replaced old filter with a new clean filter. All wiring are connected and tightened, overall basement furnace is running at normal operations at this time.


Keith F.

Keith F. Job Checkin

Customer has scheduled part replacement but wanted price for new system. If the part works they will try and make it through the winter then upgrade in spring. If part doesn't they will look at replacement option.


Greg H.

Greg H. Job Checkin

See previous invoice


Greg H.

Greg H. Job Checkin

Ac rejuv checked all filters they are clean both evaporator coils and blowers are clean checked eletrical conections on both units getting 18-19 degree delta ts. Both condenser coils are clean. Tested both drain lines. Both voltage enhancement systems read within factory spec both gateways are not pitted operation normal at this time


Clay K.

Clay K. Job Checkin

Follow up from clay. Installed burners, flame sensing system, ignition system, collector box, and uv light test ran operation normal at this time


Ashley  J.

Ashley J. Job Checkin

Attic Delta t 56 Air circulation is clean sensor cleaned Base3.1 Igniter .2 Air circulation 4.5 No Filter was in the system at the time I check however a dirty Filter was laying up in the attic Sensor 9 Voltage enhancement system 7.3 Everything was wipe down Ceiling Filter is dirty and was changed Basement Delta t 47 Filter is dirty 0 back ups Sensor was clean Voltage enhancement system 10 Sensor 8.4 Base 3 Igniter .3 Air circulation 6.5 Air circulation was cleaned


Craig D.

Craig D. Job Checkin

Did club service on airconditioning systems, checked parts and operations; both system are working normally at this time.


Craig D.

Craig D. Job Checkin

Did club service on airconditioning systems, checked parts and operations; both system are working normally at this time.


Craig D.

Craig D. Job Checkin

Did club service on airconditioning systems, checked parts and operations; both system are working normally at this time.


Craig D.

Craig D. Job Checkin

Did club service on airconditioning systems, checked parts and operations; both system are working normally at this time.


Clay K.

Clay K. Job Checkin

Club service two systems, changed all air filters, 2 - 16x25x4, 1 - 20x20x1, changed customer supplied humidifier media, test ran both systems, main house, indoor fan 6.4 amps, inducer 2.7 amps, glow bar .7, flame current 3.6 uamps, manifold pressure 3.6"wc operation normal at this time. Attic system inducer fan amps 2.5, indoor fan amps 3.5, glow bar ,6 amps, flame current 3.1 uamps, manifold pressure 3.4"wc, operation normal at this time. The duct work for the main house system is very dirty and also the exhaust removal system is noisy.


Gerald T.

Gerald T. Job Checkin

10-year-old Trane propane furnace and 10-year-old heat pump outdoor coil. The outdoor ambient temp was approximately 65 degrees, the indoor dry bulb was 68, the indoor wet bulb was 61, and the relative humidity was 65%. The cool supply air was 50 degrees and the room temperature return air was 66 degrees for a Delta T of 16. Based on the wet and dry bulb and RH readings, this is an excellent supply air temperature. Replaced the extremely dirty air filter with one provided by the customer. Measured Amperes on the air circulation system and its compartment was clean. Verified the indoor coil was clean and the circuit board and wiring were in good condition. Purged the condensation pipe and the water removal system's discharge tube with CO2 and added some descaler to the system to prevent clogs. The refrigerant pumping system's run amps were 12.2 (RLA is 22), the start amps were seven, and the air exhaust system's amps were 1.2 (FLA is 2.8). Confirmed the blades, disconnect, defrost board


Gerald T.

Gerald T. Job Checkin

10-year-old Trane propane furnace and 10-year-old heat pump outdoor coil. The outdoor ambient temp was approximately 65 degrees, the indoor dry bulb was 68, the indoor wet bulb was 61, and the relative humidity was 65%. The cool supply air was 50 degrees and the room temperature return air was 66 degrees for a Delta T of 16. Based on the wet and dry bulb and RH readings, this is an excellent supply air temperature. Replaced the extremely dirty air filter with one provided by the customer. Measured Amperes on the air circulation system and its compartment was clean. Verified the indoor coil was clean and the circuit board and wiring were in good condition. Purged the condensation pipe and the water removal system's discharge tube with CO2 and added some descaler to the system to prevent clogs. The refrigerant pumping system's run amps were 12.2 (RLA is 22), the start amps were seven, and the air exhaust system's amps were 1.2 (FLA is 2.8). Confirmed the blades, disconnect, defrost board