In Tonopah, AZ: Upon arrival, cycled unit into cooling mode. Washed and dried air filter and took temperature readings from supply and return. At unit, cleaned and tightened electrical connections. Took volts and amp draws from components. Replaced capacitor under parts warranty. Upon departure, unit working properly and within manufacturer specifications.