MY PLUMBER HEATING COOLING & ELECTRICAL
MANASSAS, VA 20109
800-280-2820

Job Locations
for dulles, va


Map of Dulles VA
CRAIG M.

CRAIG M.


Job Checkin

Attic unit Filter good Condensation line good Blower wheel needs cleaning Blower motor capacitor 7.8 Blower motor.7 Compressor 6.9 Outdoor fan motor.6 Capacitor good Contactor operational Outdoor temp 30 raining Running pressures 20 saturated temp 143.4 saturated temp 79.4 No lose or damage damage wiring Basement unit Filter good Condensation line good Blower wheel in good condition Blower motor capacitor 10.2 Blower motor 1.1 Outdoor fan motor.9 Compressor 7.1 Capacitor good Contactor operational Standing pressure 74/74 R22 No lose or damage wiring Cleaned blower motor wheel attic System are 14 and 15 years old talk with homeowner regarding upgrading system Declined for now Thank you for your business