I removed a Trane Heat Pump. I installed a Carrier 16 SEER 3.5 Ton Heat Pump. Cycled and monitored the system. Operating normally at this time. Included with the installation is a free 1 year service maintenance agreement.
I completed a diagnostic on a Gas Furnace. I determined that the thermostat froze up, I pulled the thermostat and reset power base, then recalibrated touch screen. System was operational at time of departure.
I completed a diagnostic on a 2013 ICP Gas Furnace. I determined that the system was displaying code 3 which is the pressure switches. The system is still tripping the pressure switch codes. Pressure switches need replaced.
I completed diagnostics and repair service call. I Determined trap had major blockage. I also removed Inducer and cleared excess water build up. Cycled and Monitored. System was Operating as Intended at time of eparture.
I found the leak to be coming from the condensate line. I made some adjustments and re ran the system. Could not replicate the issue. System is functional upon departure.
I made repairs to the exhaust on a Carrier 96% 80,000 BTU Gas Furnace
I found contractor not being pulled in,I found that the system is getting 24 volts to outdoor and all pressure switches are operating as they should, only item left in between is the board, board seems to be flashing code but code booklet is missing, board needs replaced.
I provided a estimate . The customer want to put a heat pump outside instead of ac that he has now