68 N High St, Bldg A Ste 113
New Albany, OH 43054
(614)636-5002

Local Reviews
for dublin, oh

Rated 5.0 out of 5 stars based on 6 customer reviews

Fast response and diagnosis.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great tune-up service

The technician arrived on time, performed AC check up and gave us a few tips on increasing AC performance. The service was professionally done. Will hire them again.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Arrived on time; finished in a few minutes.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very professional

Well done,

  • Overall Experience
  • Quality
  • Price
  • Convenience

Courteous inistallers, very responsive to our needs

Responded quickly on a very cold Sunday evening. Installation of our new furnace was next day! The guys were terrific and really cleaned up after themselves.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Furnace tuneup

He was efficient and professional and I like that he didn't try to sell me somethi,g that I didn't need.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for dublin, oh

Pooya Y.

Pooya Y. Job Checkin

I replaced the OEM evaporator coil and checked the pressures. Pressures are within manufacturers specifications and the Carrier heat pump is cooling and operating properly at this time.

I replaced the OEM evaporator coil and checked the pressures. Pressures are within manufacturers specifications and the Carrier heat pump is cooling and operating properly at this time.

Pooya Y.

Pooya Y. Job Checkin

I arrived to perform a diagnostic on an air conditioner. Upon arrival customer stated that the a/c has been cooling and it was leaking water. After further diagnostic discovered that the condensation drain line is clogged. Unclogged primary drain line with nitrogen, customer asked to have secondary drain shot with nitrogen also. Checked refrigerant pressures and system is ok on refrigerant. Checked capacitor and it will need replaced in the near future, customer declined. Noticed disconnect box is loose and coming off of wall, made customer aware, does not want to replace disconnect at this time. System operational and cooling at departure.

I arrived to perform a diagnostic on an air conditioner. Upon arrival customer stated that the a/c has been cooling and it was leaking water.

After further diagnostic discovered that the condensation drain line is clogged.

Unclogged primary drain line with nitrogen, customer asked to have secondary drain shot with nitrogen also.

Checked refrigerant pressures and system is ok on refrigerant.

Checked capacitor and it will need replaced in the near future, customer declined.

Noticed disconnect box is loose and coming off of wall, made customer aware, does not want to replace disconnect at this time.

System operational and cooling at departure.

Pooya Y.

Pooya Y. Job Checkin

I performed annual maintenance tune-up & safety check on Carrier Air Conditioning Unit. I completed checklist for tune-up and everything checked out okay. Operating within manufacture specifications at this time. System operational and cooling at my departure.

I performed annual maintenance tune-up & safety check on Carrier Air Conditioning Unit. I completed checklist for tune-up and everything checked out okay. Operating within manufacture specifications at this time. System operational and cooling at my departure.

Pooya Y.

Pooya Y. Job Checkin

I performed diagnostic on Payne Air Conditioning Unit. I determined that system was completely empty of refrigerant. I spoke to landlords via phone and we are all set for a/c replacement tomorrow afternoon. Unit not cooling upon departure.

I performed diagnostic on Payne Air Conditioning Unit. I determined that  system was completely empty of refrigerant. I spoke to landlords via phone and we are all set for a/c replacement tomorrow afternoon. Unit not cooling upon departure.

Pooya Y.

Pooya Y. Job Checkin

I performed call back install on Five Star 17 SEER 4 Ton Air Conditioner. I determined that the unit has a leak . I completed a bubble leak search. Leak found on discharge line braise joint outside. I scheduled repairs with office. We will return tomorrow afternoon to complete leak repair. System is not operational at this time.

I performed call back install on  Five Star 17 SEER 4 Ton Air Conditioner. I determined that the unit has a leak . I completed a bubble leak search. Leak found on discharge line braise joint outside. I scheduled repairs with office. We will return tomorrow afternoon to complete leak repair. System is not operational at this time.

Pooya Y.

Pooya Y. Job Checkin

I performed call back service on Carrier 13 SEER 2 Ton Air Conditioning Unit. Upon arrival this service was not required. This in a new installation already schedule for a completed Installation Inspection.


Cody J.

Cody J. Job Checkin

I performed Installation of new Five Star 80% 45,000 BTU Gas Furnace, Five Star 13 SEER 2 Ton Air Conditioning Unit , new Evap coil and removal of previous Trane HVAC system.

I performed Installation of new Five Star 80% 45,000 BTU Gas Furnace, Five Star 13 SEER 2 Ton Air Conditioning Unit , new Evap coil and removal of previous Trane HVAC system.

Pooya Y.

Pooya Y. Job Checkin

I performed diagnostic service call on Bryant Air Conditioning Unit. I determined that there are no current signs of damage due to water. Customers had work done to roof of home and believe it is causing water to enter the HVAC system. I recommended that customers get a Fall Maintenance Tune-Up & Safety Check. System is operating as intended at this time.

I performed diagnostic service call on Bryant Air Conditioning Unit. I determined that there are no current signs of damage due to water. Customers had work done to roof of home and believe it is causing water to enter the HVAC system. I recommended that customers get a Fall Maintenance Tune-Up & Safety Check. System is operating as intended at this time.

Pooya Y.

Pooya Y. Job Checkin

I arrived to give an estimate to level area for AC.


Pooya Y.

Pooya Y. Job Checkin

I returned to a home that I had recently serviced. Upon arrival found system not operational ( attic system ).. Found no low voltage present to R on t-stat. After further diagnostic discovered that the safety switch on secondary Pan was leaning and causing switch to engage and cut low voltage to R wire. Adjusted and secured float switch on secondary pan and the system kicked on operational normal. System operational and cooling at departure.


Pooya Y.

Pooya Y. Job Checkin

Client requested an estimate to replace a Bryant gas furnace and air conditioner. I recommend replacing it with a Carrier 96% Two-Stage 100,000 BTU Gas Furnace and a Carrier 16 SEER 4 Ton Air Conditioner. Included in the estimate is a 1 year free service maintenance agreement.


Pooya Y.

Pooya Y. Job Checkin

I arrived to a diagnostic service call. Repaired liquid line and added filter drier. Pressure tested to 300 for 25 minutes. Pulled vacuum to 160 with pump and 1121 without pump. Added 6 pounds. Unit is operating ok at this time.


Pooya Y.

Pooya Y. Job Checkin

I arrived to perform a call-back service to a home I had recently been out to that was experiencing the same issues as before. Upon arrival system was not operational. Noticed led light on circuit board was off, took blower door off and noticed the door switch was not engaged fully and not sending voltage through. Checked 3amp fuse and it is good. System wasn’t getting 110v due to door switch not engaging. Put a zip tie on door switch to keep issues from happening again. System operational and cooling at departure.


Pooya Y.

Pooya Y. Job Checkin

Client requested an estimate to replace a Trane air conditioner. I recommend replacing it with a Carrier 16 SEER 4 Ton Air Conditioner. Included in the estimate is a 1 year free service maintenance agreement.

Client requested an estimate to replace a Trane air conditioner.  I recommend replacing it with a Carrier 16 SEER 4 Ton Air Conditioner.  Included in the estimate is a 1 year free service maintenance agreement.

Pooya Y.

Pooya Y. Job Checkin

I completed spring tune up on a Carrier air conditioner. I visually inspected the furnace. I inspected the evaporator coil. I checked the temperature difference across the coil. Checked voltage and amps. Inspected heat pump. Checked refrigerant charge, voltages and amps. Added 1.5LBS of 410-A. I rinsed the condenser coils with water. Cycled and monitored the system. Operating normally at this time.