Randal S.

Randal S. Job Checkin

I found the humidifier to be in working condition. I answered the customer's questions and did make some adjustments to the humidity level and fully opened the water line. System is operational upon departure.

I found the humidifier to be in working condition. I answered the customer's questions and did make some adjustments to the humidity level and fully opened the water line. System is operational upon departure.

Austin M.

Austin M. Job Checkin

I installed an Aprilaire 500 Humidifier


Michael B.

Michael B. Job Checkin

I performed a Air duct cleaning that helps to eliminating dust, mold and other contaminants from your heating and air conditioning system ductwork

I performed a Air duct cleaning that helps to eliminating dust, mold and other contaminants from your heating and air conditioning system ductwork

Randal S.

Randal S. Job Checkin

I found the 2007 Goodman system coming on up until gas valve, gas valve was getting 27.5 volts and 8.15 incoming, tech tapped on valve still gas valve would not open, systems gas valve not operating as it should, ordering new valve and board for system in case issues persist after valve is replaced. I turned off the gas to unit in mean time.

I found the 2007 Goodman system coming on up until gas valve, gas valve was getting 27.5 volts and 8.15 incoming, tech tapped on valve still gas valve would not open, systems gas valve not operating as it should, ordering new valve and board for system in case issues persist after valve is replaced. I  turned off the gas to unit in mean time.

Michael B.

Michael B. Job Checkin

I am Performing our Five Star Tune-Up & Safety Check on a 2003 Rheem Gas Furnace. All readings were within manufacturer's specifications, unit operating properly at this time.


Michael B.

Michael B. Job Checkin

This 12 Year old HP has to much condensation and Mold. I found that there is No return, air handler starving for air

This 12 Year old HP has to much condensation and Mold. I found that there is No return, air handler starving for air

Michael B.

Michael B. Job Checkin

I am Performing our Five Star Tune-Up & Safety Check on a 2013 Lennox Gas Furnace. All readings were within manufacturer's specifications, unit operating properly at this time.


Michael B.

Michael B. Job Checkin

Customer states outdoor fan not spinning on the 2005 Trane. Found capacitor failure on outdoor unit

Customer states outdoor fan not spinning on the 2005 Trane. Found capacitor failure on outdoor unit

Michael B.

Michael B. Job Checkin

I Replaced the 3/4" MPT x 5/8" barbed fitting on the 2014 Payne

I Replaced the 3/4" MPT x 5/8" barbed fitting on the 2014 Payne

Michael B.

Michael B. Job Checkin

Repaired pair of 40 AMP buss fuse on Rheem AC. System cooling properly at departure.


Michael B.

Michael B. Job Checkin

Horizontal air handler in closet on 3rd floor . Water leaking through ceiling on 2 floors. Inspected air handler. Air handler had secondary drain pan. Evap primary draining properly. Unable to find leak

Horizontal air handler in closet on 3rd floor . Water leaking through ceiling on 2 floors. Inspected air handler. Air handler had secondary drain pan. Evap primary draining properly. Unable to find leak

Michael B.

Michael B. Job Checkin

Customer wanted a quote. Ac going in tomorrow


Michael B.

Michael B. Job Checkin

I replaced the Replace Compressor-Motor Surge Capacitor and added 1 pound of Refrigerant R-22 Freon into the 1996 Janitrol Air Conditioner

I replaced the Replace Compressor-Motor Surge Capacitor and added 1 pound of Refrigerant R-22 Freon into the 1996 Janitrol Air Conditioner

Michael B.

Michael B. Job Checkin

This 1995 Amana Ac does not cool well when outdoor ambient gets too high. Read notes on furnace duct work . 2# of freon was added in 2016. Ac system is low on charge again

This 1995 Amana Ac does not cool well when outdoor ambient gets too high. Read notes on furnace duct work . 2# of freon was added in 2016. Ac system is low on charge again

Michael B.

Michael B. Job Checkin

I replaced the OEM Direct Drive Blower Motor w/Capacitor on a 2010 Payne Air Conditioner

I replaced the OEM Direct Drive Blower Motor w/Capacitor on a 2010 Payne Air Conditioner