Friendly, thorough service. Found the issue.

Carl spent the time tracing a very hard-to-find short. He was able to narrow it down to wires against a pipe. I'm back in business.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Experience!

Fantastic company, great service, Carl was very thorough, friendly, and professional!! We will definitely us them again!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

great service great Tech

Carl the Tech. was on time ,neat appearance Very mannerly,well trained in his trade.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for hilliard, oh

Pooya Y.

Pooya Y. Job Checkin

144027


Pooya Y.

Pooya Y. Job Checkin

144017


Pooya Y.

Pooya Y. Job Checkin

143376


Pooya Y.

Pooya Y. Job Checkin

142923


Brian N.

Brian N. Job Checkin

I performed installation on new Five Star 96% 2 Stage Variable Speed 40,000 BTU Gas Furnace, Five Star 16 SEER 2 Ton Air Conditioner, new Evap Coil, Aprilaire High Efficiency Air Cleaner and removal of previous Bryant HVAC equipment.

I performed installation on new Five Star 96% 2 Stage Variable Speed 40,000 BTU Gas Furnace, Five Star 16 SEER 2 Ton Air Conditioner, new Evap Coil, Aprilaire High Efficiency Air Cleaner and removal of previous  Bryant HVAC equipment.

Cody J.

Cody J. Job Checkin

I completed Installation of Five Star 96% 2 Stage Variable Speed 80,000 BTU Gas Furnace, Five Star 16 SEER 3 Ton Air Conditioner, New Evap Coil and removal of previous York Air Conditioning Equipment.

I completed Installation of Five Star 96% 2 Stage Variable Speed 80,000 BTU Gas Furnace, Five Star 16 SEER 3 Ton Air Conditioner, New Evap Coil and removal of previous York Air Conditioning Equipment.

Cody J.

Cody J. Job Checkin

I performed installation on Five Star 96% 2 Stage Variable Speed 80,000 BTU Gas Furnace, Five Star 16 SEER 3 Ton Air Conditioning Unit, Honeywell T6 Programmable Thermostat, New Evap Coil, and removal of previous Carrier/Comfortmaker equipment.

I performed installation on Five Star 96% 2 Stage Variable Speed 80,000 BTU Gas Furnace, Five Star 16 SEER 3 Ton Air Conditioning Unit, Honeywell T6 Programmable Thermostat, New Evap Coil, and removal of previous Carrier/Comfortmaker equipment.

Brian N.

Brian N. Job Checkin

I completed installation on Five Star 13 SEER 3 Ton Air Conditioning Unit, New Evap Coil and removal of previous ICP Air Conditioning Unit.

I completed installation on Five Star 13 SEER 3 Ton Air Conditioning Unit, New Evap Coil and removal of previous ICP Air Conditioning Unit.

Pooya Y.

Pooya Y. Job Checkin

Customer requested an estimate to replace Trane air conditioner and gas furnace. I recommended replacing them with a Carrier 16 SEER 3.5 Ton Air Conditioner and a Carrier 80% 90,000 BTU Gas Furnace.


Pooya Y.

Pooya Y. Job Checkin

I performed diagnostic on Bryant Air Conditioning unit. I determined that condenser is not operational. I found dual capacitor has failed and needs replaced. System needs new Condensate Pump also. I gave customer quote for repair/replace. Customer decided to do a new system installation and is all set for tomorrow. I waived diagnostic fee. System is not operational at departure.

I performed diagnostic on Bryant Air Conditioning unit. I determined that condenser is not operational. I found dual capacitor has failed and needs replaced. System needs new Condensate Pump also. I gave customer quote for repair/replace. Customer decided to do a new system installation and is all set for tomorrow. I waived diagnostic fee. System is not operational at departure.

Pooya Y.

Pooya Y. Job Checkin

I performed a diagnostic call on a Weather King air conditioner. Upon arrival found system not operational at all. After further diagnostic discovered that the step down transformer has failed and it isn't sending voltage through. Replaced transformer and checked refrigerant pressures, all is ok at this time. Recommended system replacement in the near future, System operational and cooling at departure.

I performed a diagnostic call on a Weather King air conditioner. Upon arrival found system not operational at all. After further diagnostic discovered that the step down transformer has failed and it isn't sending voltage through. Replaced transformer and checked refrigerant pressures, all is ok at this time. Recommended system replacement in the near future, System operational and cooling at departure.

Pooya Y.

Pooya Y. Job Checkin

Diagnostic call on a Carrier heat pump. Upon arrival found system not operational and the thermostat was blank. I found the condensation drain clogged. Blew out drain with nitrogen and made customer aware that if line gets clogged again, I'd recommend installing a pump and draining into washer drain. System operational and cooling at departure.

Diagnostic call on a Carrier heat pump. Upon arrival found system not operational and the thermostat was blank. I found the condensation drain clogged. Blew out drain with nitrogen and made customer aware that if line gets clogged again, I'd recommend installing a pump and draining into washer drain. System operational and cooling at departure.

Pooya Y.

Pooya Y. Job Checkin

I performed diagnostic on Aire-flo Air Conditioning Unit. I determined that system low on refrigerant. I Explained leak search, repairs and replacement to customer. Customer decided to only charge system for now to try and get through the season. System operational and cooling at time of my departure.

	I performed diagnostic on Aire-flo Air Conditioning Unit. I determined that system low on refrigerant. I Explained leak search, repairs and replacement to customer. Customer decided to only charge system for now to try and get through the season. System operational and cooling at time of my departure.

Pooya Y.

Pooya Y. Job Checkin

I performed diagnostic on Aire-flo Air Conditioning Unit. I determined that system low on refrigerant. I Explained leak search, repairs and replacement to customer. Customer decided to only charge system for now to try and get through the season. System operational and cooling at time of my departure.

I performed diagnostic on Aire-flo Air Conditioning Unit. I determined that  system low on refrigerant. I  Explained leak search, repairs and replacement to customer. Customer decided to only charge system for now to try and get through the season. System operational and cooling at time of my departure.

Pooya Y.

Pooya Y. Job Checkin

I performed In Warranty Part replacement on Carrier 13 SEER 2.5 Ton Air Conditioner. I replaced OEM Evaporator Coil. System is now operating within specifications.

I performed In Warranty Part replacement on Carrier 13 SEER 2.5 Ton Air Conditioner. I replaced  OEM Evaporator Coil. System is now operating within specifications.