I completed a diagnostic on an A/C. I replaced dual capacitor and inspected the general condition of the equipment. I also provided an estimate for a new system as this is aging equipment that is having multiple recurring problems. Customer will get back with us.
Customer was scheduled for an estimate on a new system
I provided client with an estimate for a new full HVAC system!
upon arrival customer stated that it wasn’t keeping temp. When arrived at furnace it wasn’t running but wasn’t throwing a fault code either. Cycled furnace and allowed to run with no issues. Temp rise at 50 degrees. Found gas pressure at 3.72”wc so lowered to 3.5. Cycled furnace multiple times and allowed to run 30 minutes with no problems whatsoever. Set stat to 70 per customer request. Furnace operational upon departure.
Upon arrival I completed diagnostics and found the OEM Inducer Motor needs replaced. The customer opted not to go forward with this repair at this time.
I completed a diagnostic. Customer explains that furnace works intermittently. Furnace worked the entire time I was here. Cleaned flame sensor, blew out drains, checked combustion readings. From customers description of the issue it sounded like it was kicking out on low flame current. Everything worked on repeated cycling of furnace. Furnace is operational on my departure.