I completed a diagnostic service call on an air conditioner. I found the float to the condensate pump stuck, after flushing it out float it did not stick any longer. The safety switch had tripped. If the condensate pump repeats this problem we will bring a 120 VAC pump and replace it.
After removing the Trane gas furnace and air conditioner, I installed a Five Star 96% 2 Stage Variable Speed 80,000 BTU Gas Furnace 5T 21" and a Five Star 16 SEER 2 Ton Air Conditioner. Cycled and monitored the system. Operating normally at this time. Included with the installation is a free 1 year service maintenance agreement.
Client requested an estimate to replace a gas furnace and air conditioner. I recommend replacing it with a 96% 60,000 BTU GAS FURNACE AND 13 SEER AC.
Performed a sma tune-up and safety check-up for a AC unit. Found outside coil full of debris, advise customer to clean out around the outside coil. Technician found a weekend capacitor at the AC unit rated 45/5 Actual 39/3.9, Client opted to replace at this time. AC unit appears to be slightly low on refrigerant, however delta T/the temperature difference between supply and return air was at 19 and in nRange. Customer opted not to have refrigerant charged into the system at this time. Technician advised that if the system could not keep up during the summer hot months to call us back to recheck it.
I completed a full install upon departure system was working as it should.
I completed a full install upon departure everything was working as it should.