The office staff was very professional, and some answered the phone! The technician found the problem, and got it fixed very quickly
Excellent and very helpful with programming my computer and phone.
couldn't ask for any better
Great price. Most workers very pleasant. Could be better with being cleaner in owner property
The installation Tecs were courteous, knowledgeable and efficient installing my outside unit.
The instal guys need a raise $20 an hour min. Super great guys
Remove and replaced air handler unit in attic and restarted per. Manufacturers Specification. Thank you for choosing Ray and Son to provide you with your indoor climate comfort today !
Removed existing system and replaced with 3 Ton 14 seer system in attic , flushed and purged existing copper line set , evacuated ,released charge and started system per. Manufacturers Specications. Also needed to quote for rewrap , seal on leaking duct system and duct cleaning . Thank you for choosing Ray and Son to provide and enhance your indoor climate comfort today !
Remove existing pkg. unit and replaced 14 seer pkg. unit . Did proper start up per manufactures specifications . Thank you for allowing Ray And Son to provide and enhance your indoor climate comfort today !
Removed 3.5 Ton r-22 condenser ,evaporator coil , and line set, replaced with R-410A same components , evacuated ,released charge and did restart to manufactures specifications . Thank you for allowing Ray and Son to enhance your indoor climate comfort today !
Removed 3.5 Ton r-22 condenser ,evaporator coil , and line set, replaced with R-410A same components , evacuated ,released charge and did restart to manufactures specifications . Thank you for allowing Ray and Son to enhance your indoor climate comfort today !
Removed and replaced downstairs and upstairs air handlers with r-22 TXVs evacuated and set charge to manufactures specifications. Thank you for allowing Ray and Son to provide your indoor climate comfort today !
Installed 2ton system and ductwork in home with no prior duct system ,started and set per manufactures specifications. Thank you for choosing Ray and Son to provide and enhance your indoor climate comfort today !
Remove existing 3 Ton lit system and replace with 15seer split system and did duct addition with other duct modifications started and set system per manufacture specifications . Thank you for choosing Ray and Son to provide and enhance your indoor climate comfort Today !
Removed 21 year old system and replaced with 3 Ton 2 stag. 16seer system, started up per manufactures specifications and confirmed proper zone operation. Thank you for allowing Ray and Son to enhance your indoor climate comfort today !
Removed and replaced showroom air handler unit , removed flex duct return, replaced with hard pipe , insulated and sealed return and supply boxes , reset refrigerant charge to manufactures specifications . Thank you for choosing Ray and Son to provide you , your employees and customers your indoor climate comfort today !