Jason H.

Jason H. Job Checkin

Checked out plug for the stove. Everything was tight on it. Checked panel and breaker for stove. Everything works as it should.


Jason H.

Jason H. Job Checkin

installed new fill valve,flapper and supply line


Jason H.

Jason H. Job Checkin

installed a new prv and a customer supplied Kf and to customer supplied fill value everything customer supplied I will not warranty but the prv has a 1 year parts and labor psi on the house is 65


Jason H.

Jason H. Job Checkin

Install 1/2 hp disposal under right side of the kitchen sink.


Jason H.

Jason H. Job Checkin

install customer supply sink and faucet


Jason H.

Jason H. Job Checkin

install customer supplied faucet in powder room bath we also fixed the drain stopper in the master bathroom tub


Jason H.

Jason H. Job Checkin

Replaced blown run capacitor to upstairs ac. amps ok at 7.2. freon 261/83 14 subcool 22 superheat. upstairs temp 83.


Jason H.

Jason H. Job Checkin

Found both main and upstairs units frozen. thawed out both. main floor filter was completely impacted; freon to that unit ok. txv to upstairs unit was throttled down in mostly closed position. opened up valve by warming bulb now wide open and flooding coil-252/77 30 subcool 26 superheat. the apex circuit of the evaporator coil has never sweated back since it was installed. recommend replacing coil; Goodman ac unit for upstairs is brand new. replaced blown run capacitor at the barn.


Robert   W.

Robert W. Job Checkin

Found air conditioner drain to upstairs unit partially clogged tripping float switch. flushed drain. refrigerant at 272/119 5-8 super-heat(piston). this units coil was replaced in 2014.


Robert   W.

Robert W. Job Checkin

Found upstairs unit extremely low on freon; found compressor making a grinding noise/not pumping refrigerant. Apparently this air conditioner unit was replaced in 2012 with a dry charge air conditioner but the 15 year old evaporator coil which is leaking was not replaced. this more than likely caused damage to the compressor. recommend upgrading air condiitoner and coil or complete system.


Amber  D.

Amber D. Job Checkin

Cut out the old drain system and the garbage disposal.Installed a new Studevent new drain work and customer supplied faucet.


Robert   W.

Robert W. Job Checkin

Completed Air Conditioner preventative maintenance on two units.


Ben G.

Ben G. Job Checkin

Removed wash machine hoses for customer.


Robb C.

Robb C. Job Checkin

Furnace no heat due to main lennox furnace to have a bad control board recommend replacing furnace due to age.


Robb C.

Robb C. Job Checkin

Completed Air Conditioner preventative maintenance on two unit.