Jason went quietly about his work. He reported what he found, made suggestions. I was impressed.
Response from RS Andrews:
Thank you for taking your time and completing the review!
We furnished, wired, and Installed a breaker to separate double tapped breaker code violation. We separated the neutrals as required by code since they were multiple wires per screw. We furnished, wired, and replaced a tandem breaker as required by code since it was over-sized and the wrong type. We furnished and installed 2 connectors on wires coming into the panel as required by code.
Service fee call. Performed panel maintenance and tightened all connections.
We furnished, wired, and replaced the 2 lights at the back of the home with 175 watt equivalent LED floodlights. Troubleshot 2 outlets, 1 per sons room, that had no neutral. Furnished, wired, and replaced said outlets as the wires were loose. Outlets work as they should now.
replace American diverted stem for 3 handle tub and shower valve also unclog tub drain line as well for guest bathroom
1- replaced leaky angle stop under kitchen sink. hot side. 2- replaced PRV Valve.
ac unit wasn't cooling found compressor an fan motor not coming on due to bad capacitor, replaced 40/5 cap an started unit an everything checks out ok
Troubleshot fan in the living room. Found fan installed on a non fan rated box. Removed fan as it is improperly installed and can fall. Troubleshot fan in the upstairs bedroom. Found fan installed on a non fan rated box. Removed fan as it is improperly installed and can fall. Troubleshot fan in the upstairs bedroom. Found fan installed on a non fan rated box. Removed fan as it is improperly installed and can fall.
Replaced hall bath toilet with Kohler high line.
Customer took garbage disposal apart and kitchen faucet leaking. Re-work plumbing drain configuration under k/s END TASKS*/
Estimate to install a switch and switch leg in the kitchen by the sink area for under cabinet lighting,customer provided puck lights,a switch, switch leg in the kitchen by the microwave for under cabinet lighting, customer provided puck lights, and a new wire and box to relocate light above the island in the kitchen.
Completed Air Conditioner preventative maintenance on two units.
Estimate on replacing Tub and Shower Valve.
Estimate to installed 1/2 gas line with gas valve for gas stove must run gas line in crawl space.
Return from preventative maintenance visit and install attic tent staircase to attic and close.
Completed furnace preventative maintenance on one unit.