Lauren did a great job presenting and answering questions during this online presentation.
Our company is in the early stages of developing a service department. The software that was shown to me was very nicely laid out and easily accessible. I'm looking for software that will seamlessly interface with our accounting system.
HVAC Planned Maintenance Roof 001 roof top unit Trane QRS990 J3254774: Preventative Maintenance - Quarterly -Inspect condensor or cooling elements. -Inspect control box, associated controls, wiring and connections. -Clean or replace air filter. -Remove and add refrigerant -Inspect conditioned airflow system (ductwork)—check for leaks. Roof 004 Roof top unit Trane QRS990 J3254777: Preventative Maintenance - Quarterly -Inspect condensor or cooling elements. -Inspect control box, associated controls, wiring and connections. -Clean or replace air filter. -Remove and add refrigerant -Inspect conditioned airflow system (ductwork)—check for leaks. Roof 002 Roof top unit Trane QRS990 J3254775: Preventative Maintenance - Quarterly -Inspect condensor or cooling elements. -Inspect control box, associated controls, wiring and connections. -Clean or replace air filter. -Remove and add refrigerant -Inspect conditioned airflow system (ductwork)—check for leaks. Roof 003 Roof top unit Trane QRS990 J32
HVAC Preventative Maintenance Roof 001 Daikin QRS990 J3254774: Preventative Maintenance - Quarterly -Inspect condensor or cooling elements. -Inspect control box, associated controls, wiring and connections. -Clean or replace air filter. -Remove and add refrigerant -Inspect conditioned airflow system (ductwork)—check for leaks. Roof 002 Trane QRS990 J3254775: Preventative Maintenance - Quarterly -Inspect condensor or cooling elements. -Inspect control box, associated controls, wiring and connections. -Clean or replace air filter. -Remove and add refrigerant -Inspect conditioned airflow system (ductwork)—check for leaks. Roof 003 Trane QRS990 J3254776: Preventative Maintenance - Quarterly -Inspect condensor or cooling elements. -Inspect control box, associated controls, wiring and connections. -Clean or replace air filter. -Remove and add refrigerant -Inspect conditioned airflow system (ductwork)—check for leaks. Roof 004 Trane QRS990 J3254777: Preventative Maintenance - Quarterl
The following is an estimate for the replacement of your broken fan. This quote includes the estimated time for labor, parts for the repair, and the factory trained technician will startup and monitor your newly repairs unit. Please let the office know if you have any questions about this quote or need to request changes. Boiler Controls Repair Boiler Room BMS Cleaver-Brooks XYZ123 K0098223: Thermostat failed - repair Inoperable Deficiency for Roof 001 Trane QRS990 J3254774: Broken compressor
HVAC, Commercial Hot Water, and Refrigeration Preventative Maintenance Roof 001 Trane QRS990 J3254774: Quarterly PM Roof 002 Trane QRS990 J3254775: Quarterly PM Boiler Room 002 Gas Tank Cleaver-Brooks QRS990: Standard Boiler Quarterly Boiler Room 001 Gas Tank Cleaver-Brooks QRS990: Standard Boiler Quarterly Behind Building 003 Manitowoc QRS990 J3254776: Quarterly PM Behind Building 002 Manitowoc QRS990 J3254775: Quarterly PM Behind building 001 Manitowoc QRS990 J32454774: Quarterly PM Deficiency for Roof 001 Trane QRS990 J3254774: Bad compressor
HVAC Preventative Maintenance Roof 001 Daikin QRS990 J3254774: Preventative Maintenance - Quarterly -Inspect condensor or cooling elements. -Inspect control box, associated controls, wiring and connections. -Clean or replace air filter. -Remove and add refrigerant -Inspect conditioned airflow system (ductwork)—check for leaks. Deficiency for Roof 001 Daikin QRS990 J3254774: You can talk to type Inoperable Deficiency for Roof 001 Daikin QRS990 J3254774: Safety. Inaccessible system.