Job Locations
for deer park, tx

Pete L.

Pete L. Job Checkin

Found furnace door not fastened right fasten door right and checked operations


Pete L.

Pete L. Job Checkin

Check blower motors and amperage on blower motors check condenser fan motor amperage check evaporator coils and condenser coil check amperage on compressor checked all drain lines check temperature differential inside building


Alex T.

Alex T. Job Checkin

Warranty: limit switch connector on blower motor was disconnected, likely from when we reinstalled motor housing while replacing blower motor. Reconnected connector, and furnace started normally.


Joseph S.

Joseph S. Job Checkin

Customer wanting in house financing, on fixed income & they do not have money to put down and need low monthly payments. They are not interested in doing any 3rd party financing.


Matthew J.

Matthew J. Job Checkin

Ac repair and maintenance: unit was not cooling properly. Noticed that the compressor was not running but the fan was. Checked capacitor and had no readings in the compressor side of the capacitor. Replaced capacitor and got unit running with a 14 split. Also changed out filter and checked unit in attic. Blower motor was an ecm and pulling to correct amps. Poured bleach down drains as well. Unit may possibly be under sized a heat load will be needed to be sure. Talked to customer about our maintenance plan as well. 4444: preformed maintenance unit was pressures were in range as well a amp draws and capacitors for the outdoor unit. Filter needs to be changed indoors. Blower motor amps and capacitor were in range as well. Poured bleach down drains as well.


Alex T.

Alex T. Job Checkin

AC repair: replaced condenser fan motor on condensing unit. System is operating normally at this time.


Alex T.

Alex T. Job Checkin

AC Repair: condenser fan motor is seized and will not turn. Recommend replacing condenser fan motor.


Joseph S.

Joseph S. Job Checkin

System performing fine, Thermostat is not reading the temperature correctly causing the unit to shutoff early and not cool the upstairs. Customer not interested in any repairs at this time.


Alex T.

Alex T. Job Checkin

Maintenance: wants to get 3 rooftop units maintained.


Alex T.

Alex T. Job Checkin

Maintenance: Bronze Comfort club memberships for 3 units for one year. Semi-annual system maintenance and filter change, supplied by owner. After hours service, and 10% discount on repair labor. Performed maintenance on all three units.


Joseph S.

Joseph S. Job Checkin

Replaced blower motor and tested unit for performance, all pressures were meeting manufacturer specifications and unit was cooling well.


Joseph S.

Joseph S. Job Checkin

Diagnosed blower motor failure and will be replacing.


Alex T.

Alex T. Job Checkin

Low voltage fuse on transformer is tripped. Replace fuse and system is operating normally. Tested heat strips, and compressor amps and both are in range.