Checked drains on both systems of 607 and 505, primary drains are clear. The problem is where the drains tie into main drain lines under building. Will need a plumber to fix the back up of water in units.
Pressures and super heat readings on gauges show that the system has a restriction in the system. Has been narrowed down to the piston metering device.
System is about 2lbs low on refrigerant, suggest a leak check to determine where the loss is coming from.
System is about 2lbs low on refrigerant, suggest a leak check to determine where the loss is coming from. System is roughly 2lbs low on R410a
Performed diagnostic on system, determined system is roughly 2lbs low on r410a. Tried contacting home owner to approve repair, could not get into contact.
Spoke with customer and they will call back after talking with husband.
Found condenser coil leaking, condenser needs replacing, to replace condenser will be 400.00, to replace condenser coil will be 600.00
Maintenance: performed cooling maintenance. System achieving 19 degree temperature split. Amp draws are in range and drains are clear at this time.
Repair: zone panel for 2 zone home had error reading discharge air temperature. Recommend replacing zone board to correct this issue. Zone board has been replaced and system is heating normally at this time.
Repair: ignitor was mounted in improper orientation. Unable to ignite gas from burner manifold. Used bracket from universal kit to properly mount ignitor in place. Heat exchanger and furnace are in overall poor condition. No visible cracks in heat exchanger, but channels are extremely rusty. Recommend replacing furnace to prevent cracks from forming and leaking carbon monoxide and unburned gasses into living space.
repair: high pressure switch on condenser is stuck open. Tested system without pressure switch for 20 minutes and no high pressure spikes detected. The high pressure switch needs to be replaced to return the system to proper operation.