Great folks!!!

On time, professional and thorough. Toby was a great tech. Gave a complete report and future appointed already made.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

This was our semi-annual checkup. Mathew was our tech and he was on time, very professional but personal. He supplied us with the documentation of what checks he performed. He was very efficient and quiet. He performed his inspection in a balanced amount of time. It was a pleasure to have him take care of our system. He is definitely a 5-star employee. We recommend him and his company without reservation.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for pasadena, tx

Pete L.

Pete L. Job Checkin

Found drain line plugged blue drain line raised secondary drain pan checked operations


Pete L.

Pete L. Job Checkin

Check blower motor and amperage of blower motor check blower motor capacitor found capacitor weak replace capacitor checked all electrical connections checked all ductwork check primary drain line and secondary drain line replace media filter took temperature differential check amps on condenser fan motor and compressor check capacitor and contactor check Freon levels


Alex T.

Alex T. Job Checkin

Maintenance: Performed system heating maintenance. System is heating normally at this time achieving a 41 degree temperature rise. Blower motor and inducer amp draws are in range. New filter has been installed.


Matthew J.

Matthew J. Job Checkin

Duct fogging: house had no power due it moved into and nobody currently living there. Customer will call to reschedule.


Matthew J.

Matthew J. Job Checkin

Tune up: unit is functioning properly and producing a 20 degree split. Condenser was a little dirty and was spayed down and cleaned with water. Electrical components for the system are in range and capacitors or are good. Ductwork is very old and deteriorating. Recommend replacing all of the duct work in the future and system replacement options. Need to return for duct fogging.


Joseph S.

Joseph S. Job Checkin

Called and left a vm.


Alex T.

Alex T. Job Checkin

Ac repair: tested wires to thermostat and resecured to the base of the nest thermostat. System is operating normally at this time with a 16 degree temperature split. Could potentially be an issue with the nest thermostat.


Matthew J.

Matthew J. Job Checkin

Ac repair: unit was functioning properly. Air flow to bedroom was a little low adjusted the dampers that were accessible or could find. Customer was concerned about the thermostat. Thermostat showed no signs of malfunctions apon inspection. Was not able to verify if all the ducts had dampers. If not recommend adding them and adjusting airflow further


Alex T.

Alex T. Job Checkin

Maintenance: system is operating normally at this time. Achieving a 16 degree temperature split. Amp draws are in range and capacitors are in range.


Alex T.

Alex T. Job Checkin

Ac repair: several wires were charred at the condensing unit. Tested ohms on compressor, ohms are in range. Recommend replacing system due to age, but wire repair can be attempted. Repaired wires and unit is operating normally. Capacitors are in range. Amp draws are high, but still in range. Achieving a 19 degree temperature split. System is 19 years old.


Alex T.

Alex T. Job Checkin

AC Repair: Rewire heater relays. Change setting on control board to fixed variable speed.


Lori P.

Lori P. Job Checkin

Winter Maintenance. Trane indoor gas furnace Model: TUD1B060A9H31BC Serial: 18172RA41G found in good running condition. Gas flames were strong, blue color. Blower motor housing and air return chase found with light grey build up from dust. Customer changes filters on a normal basis, recommendation to add in a UV light filter like Air Scrubber to help eliminate dust build up.


Alex T.

Alex T. Job Checkin

System is operating normally at this time. Duct on supply plenum is securely attack had to plenum.