5712 Highland Rd
Santa Fe, TX 77517
346-326-2665

Local Reviews
for rosenberg, tx


Job Locations
for rosenberg, tx

Alex T.

Alex T. Job Checkin

AC repair: discharge air temperature sensor on Zone board is falsely reading an overheat. Giving overheat error even when temperatures are not hot enough for an overheat. Recommend replacing the discharge air temperature sensor on Zone board resume normal function of Zone board.


Matthew J.

Matthew J. Job Checkin

Maintenance: unit was functioning properly and producing a 20 degree split. Compressor and fan motor amps were in range along with the capacitor. Pressures were in range as well with a 8 subcool. Indoor unit amp draws were in range. It is ECM blower so no capacitor. Coil is sitting on foam to increase pitch of draining due to bent cabinet was causing some water to drip on to unit.


Alex T.

Alex T. Job Checkin

AC Repair: Condenser fan motor has open windings, tripping the circuit breaker on unit startup. Recommend replacing the condenser fan motor.