Great service! Showed up on time and made sure everything was working properly before the technician left.
Called on Sunday afternoon, Matthew was there before 800 am on Monday morning as promised.
Alex Tobey was extremely knowledgeable and patient. We are still waiting on the actual amount.
Suction line sweating this is normal check Freon levels all good at this time unit is operating at normal conditions
System was charged with r410a in the end of may, system has leaked out again, leaked check was preformed and determined it was evap coil.
Check drain lines primary line draining correct no water and drain pan found thermostat fan on constant on creating humidity advised homeowner to leave thermostat on auto
Found drain line plugged cut drain line blew out drain line reconnected drains and watch drain flow all good at this time
Fogged upstairs and downstairs unit check blowers and amperage checked all electrical connections checked all duct work check evaporator coils checked primary drains checked secondary drains check amperage on compressors and condenser fan motors check contactors check Freon levels check capacitors found one capacitor weak replace capacitor 45-7.5 all operations normal at this time
Bad heat exchanger we will be swapping out on Saturday 4/3/2021 as long as the unit is delivered by that time. Heat exchanger replaced and running perfectly.
Converted furnace from LP gas to propane gas checked operations all good at this time
Replaced flame rollout sensor tested unit all good at this time
Bad board on Condenser straight from manufacturer, replaced and unit is working.
maintenance: Performed heating maintenance on two systems. Achieving 36 degree temperature rise in heat. Emergency drain pan on upstairs unit is rusting. Recommend replacing drain pan to prevent water damage to ceiling.
Installed 3.5 Ton Gas system, gas furnace, coil, condenser, condensing pad, flush solvent, copper, 10 Year Parts/10 Year labor & nest thermostat.
Cleaned ductwork master bedroom, living room, den & office system. Fogged system as well.
Ac repair: primary drain line was clogged, sending water into supply plenum, and causing a drip onto the ceiling in master bedroom. There are also PDC joints on secondary drain line that are unglued. Blower wheel is very dirty, has approximately half inch dirt build up. Recommend clearing primary drain line, and repairing sections of PVC, and cleaning blower wheel and also signing up for Comfort Club membership to help with preventative maintenance in future. Primary drain line is clear, drained one full gallon of water through drain line without issue. Repaired secondary drain line and perform heating maintenance. System is achieving 28 degree temperature rise.
Disinfected system & sealed units. Performed fogging additionally.