Panel on condenser came off, added new screws and secured back on unit. Changed customer filters.
Condenser fan is not the issue and is working properly, after reviewing system I found indoor and outdoor unit frozen, this is caused by low air flow due to blower failure, dirty filter or its low on refrigerant. Indoor ice needs to thaw before pressures can be checked. Will be scheduling for tomorrow 5/4/2021 at 2PM.
Removed leaking coil installed new warranty coil cold vacuum and recharge unit
Repaired duct and and blue drain line vacuum water out of drain pan
Installed 4 Ton 16 Seer Electric system with drain pan, float switch, filter drier. 10 Year Parts/10 Year labor.
Remove old drain pan, install new drain pan, attach drain lines and blow drain lines. Pete passed job off to Joseph to sell system & customer decided to replace the entire system.
Warranty: blower motor is shorted and only spinning at half speed. Need to replace blower motor under manufacturer warranty. Replaced blower motor and system is operating normally at this time.
Install: installed Goodman Heat Pump unit on a 20' raised platform. Also replaced indoor air handler.
Maintenance: performed heating maintenance on two electric air handlers. Both systems achieving 31 degree temperature rise. Ductwork on downstairs unit is starting to fail in some spots. Recommend replacing a few ducts to maintain efficiency.
Installation: came out to install new condenser fan motor along with adding a pound of refrigerant. System is much quieter and running more smoothly.
Install: installed Aprilaire dehumidifier. Re-ran the ductwork to the new dehumidifier, wired the new digital humidistat in. System is operating normally at this time.
Ac repair: upstairs was not cooling. After inspection noticed barriers need to be changed on tstat. Out door unit had a bad capacitor and fan motor replaced both and got unit running. Unit is very old and cooling slowly at this time. Recommend looking into replacement options.
AC Repair: Bottom cover for refrigerant lines and low voltage connections has fallen off the unit. Reinserted the cover and replaced 2 screws to secure the cover to the unit. Verified the cover was secure.
AC Repair: Airflow to the laundry room was too forceful. Cut the airflow back down to that room to provide better heating to the room.
Heat strip on heater is only activating one of two coils. Recommend replacing heat kit. Heater is operating normally at this time.