Replace thermostatic mixing valve with Moen diverter brush nickel trim and oversized face plate to cover hole


Joseph.Wade@supremeairllc.com

Joseph.Wade@supremeairllc.com Job Checkin

Fall pm on 11/07/19 On arrival set unit to call for heat measured supply and return air temp measured voltage and amps Checked electrical connections checked voltage and amps checked air filter needs to be replaced but customer doesn’t have one also voltage absorption system is below spec so I suggested replacing now to avoid future problems I gave quote for customer accepted replaced the voltage absorption system also aprilaire air filter model #413 checked blower motor checked EWP and LWP it was low I pump it back up 65/60 Psi checked water temp unit tested unit operating very smoothly without any hesitating or lag unit operating normal at this time. Recommended duct cleaning and uv lights installation also single or hole house surge protector to avoid future problems. Collected $95 for capacitor replacement and $63.75 for aprilaire air filter model #413 replacement total $158.75 on C.C on file.


Yonas M.

Yonas M. Job Checkin

GEO WATER FURNACE ENVISION FALL PM WASHINGTON GROVE MD

GEO WATER FURNACE ENVISION FALL PM WASHINGTON GROVE MD

Yonas M.

Yonas M. Job Checkin

GEO water furnace Envision fall pm Washington Grove

GEO water furnace Envision fall pm Washington Grove

Joseph.Wade@supremeairllc.com

Joseph.Wade@supremeairllc.com Job Checkin

Replace gate valve and bring incoming service up to code. In order to bring up to code we would add in a dual check and prv in line for code purposes. After I installed dual check and prv on main line I then went and tested the shower diverter. The diverter is a fixed valve body which I can’t clean out. Will need to replace and cut into the wall but will add access panel for easier access for future maintenance.


Joseph.Wade@supremeairllc.com

Joseph.Wade@supremeairllc.com Job Checkin

Upon arrival found shower to be having low pressure. So I went to try and do my procedures and found the gate valve not closing off the water to shut the house down. So gave recommendations on replacing gate valve and would need to start here in order for us to properly diagnose the low shower pressure issue.