Arrived at customers house for system Check. On arrival customer showed me to air handler and closet. Remove the filter in the filter look relatively clean. After looking under the evaporator coil the evaporator coil is heavily covered with debris. Strongly urged customers to consider a pull and clean. Wrote customers estimate and sent. Unit was putting out acceptable delta-t, blower motor looks relatively clean. Unit already has a UV light. All electrical wiring with secure. Next went outside 2 condenser. Condenser was at a diagonal angle on the pad. Liquid line increase and decrease in pipe diameter a couple times. Unit compressor was either edging on it's limit or peeking over maximum of two amps. Suggested a hard start kit to the customers and percents an estimate. All pressures in readings were of acceptable limits. All electrical wiring with secure. Proper voltage being sent across contactors. Capacitor with an acceptable limits. Check in with customers and customers were happy w