Upon arrival thermostat not operational air handler not operational condenser not operational. Technician found system filter totally clogged recommend replacement. Technician found emergency pan safety tripped due to pain being full of water recommend clearing water out of drain pan. Technician found condensation line clogged recommend line clearing. Technician found condenser capacitor failed recommend replacement. Technician found condenser fan motor failed recommend replacement replacement for this motor is A 9 to 10 day wait, clients agreed with all other repairs except replacement of motor. Technician recommended service agreement plan client disagreed. Technician could not measure refrigeration due to lack of condenser fan motor along with clogged filter.