Office: Jake & Luis need for about 2 hours. Will need to remove blower wheel to clean & remove line set cover to see condition of condensate flex line. Recommend evaporator head cleaning Arrived at the home and proceeded to look into why the unit is leaking on the left side. Tried to mimic condition but it didn’t leak while in front of the unit. I checked levelness of the unit and it 1/32” leaning to the left. Not enough to cause leak. Poured water into the pan and it is draining out but slow. Checked blower wheel and it is impacted with dust which will slow air flow. Drain pan and drain line cleaned at last trip. 8-16-2024 Performed mini split blower and coil clean. Also removed drain line cover to verify that there is no kinked hose. Raised up header on the left side to pitch drain more towards the right. System is working and draining properly.