Job Checkin

Found condenser breaker tripped upon arrival. Flipped breaker and it immediately tripped again. Went to the condenser and took the load out of the circuit completely and the breaker wouldn’t trip. Then introduced the current just to the fan motor and the breaker would stay on. Checked the compressor to ground and it was okay, checked between the windings and it was okay, determined it was in a lock rotor state as soon as voltage was applied. Compressor harness was reading exact voltages when not applied as well. Need to order new compressor, refrigerant will need to be recovered and then pumped back in after replacement, recommend 2 guys 3-4 hours since we are lifting a compressor onto a roof through a tight access hole. Left system in the same state that I arrived and disconnect is upside down and off at the condenser.