Keith H. Job Checkin

EQUIPMENT ESTIMATE 5 TON AIR HANLDER WITH 4 TON OUTDOOR UNIT. HOME IS 2100 SQUARE FEET. RECOMMEND 5 TON SYSTEM.


Stuart M.

Stuart M. Job Checkin

PERFORMED PMP INSPECTION ON ONE SPLIT HEAT PUMP UNIT CHECKED AMP DRAW OF MOTORS TESTED RUN CAPACITORS TO BE WITHIN MANUFACTURERS RATING VERIFIED TEMP SPLIT ACROSS COIL CLEANED OUTDOOR COIL TIGHTENED ELECTRICAL CONNECTIONS INSPECTED CONDITION OF UNIT UNIT RUNNING NORMALLY IN COOLING AT TIME OF INSPECTION. WEATHER MASTERS RECOMMENDS FOLLOW UP INSPECTION IN FALL FOR HEATING SIDE OF SYSTEM.


Keith H.

Keith H. Job Checkin

FOLLOW UP VISIT FOR NEW INSTALL 2 SYSTEM. DIAGNOSIS: TESTED BOTH UPSTAIRS AND DOWNSTAIRS UNIT. RAN EQUIPMENT FOR 15 MIN AND VERIFIED FREON LEVELS. WEATHER MASTERS DID ADJUST CHARGE ON BOTH SYSTEMS TO FACTORY SPECS. BOTH UNITS ARE RUNNING GREAT WITH NO ISSUES.


Stuart M.

Stuart M. Job Checkin

WEATHER MASTERS COMPLETED THE FOLLOWING: - REMOVE AND HAUL AWAY EXISTING 3 TON SPLIT HEAT PUMP SYSTEM & 3.5 TON SPLIT HEAT PUMP - WEATHER MASTERS WILL INSTALL NEW 3 TON 14 SEER DAY AND NIGHT SPLIT HEAT PUMP FOR UPSTAIRS - WEATHER MASTERS WILL INSTALL NEW 3.5 TON 14 SEEER DAY AND NIGHT SPLIT HEAT PUMP FOR DOWNSTAIRS. - WEATHER MASTERS WILL INSTALL 2 NEW HONEYWELL 8000 wifi PROGRAMBLE THERMOSTATS. - WEATHER MASTERS WILL INSTALL 2 NEW CONDENSATE FLOAT SAFTY SWITCHES. - WEATHER MASTERS WILL INSTALL 2 NEW 30X20 BAR TYPE FILTER GRILLS. - WEATHER MASTERS WILL CONNECT NEW EQUIPMENT TO EXISTING DUCT WORK USING CUSTOM METAL TRANSITIONS. - WEATHER MASTERS WILL R11 FLUSH FREON LINES AND BLOW OUT CONDENSATE. - WEATHER MASTES WILL INSTALL 2 NEW FUSED SAFTY DISCONNECTS W/ NEW 3/4IN ELECTRICAL WHIPS. WARRANTY- 10 YR PARTS, 10 YR COMPRESSOR , 1 YR LABOR. PRICE INCLUDES ALL LABOR , MATERIAL TO COMPLETE THE JOB


Keith H.

Keith H. Job Checkin

Estimate new system.


Stuart M.

Stuart M. Job Checkin

PERFORMED PMP INSPECTION ON PACKAGE HEAT PUMP UNIT CHECKED AMP DRAWS OF MOTORS TESTED RUN CAPACITORS FOR PERFORMANCE VERIFIED SEQUENCE OF OPERATIONS FOR DEFROST CYCLE CHECKED TEMPERATURE RISE TIGHTENED ELECTRICAL CONNECTIONS INSPECTED OVERALL CONDITION OF UNIT UNIT RUNNING NORMALLY IN HEATING AT THIS TIME. UNIT HAS EXCESSIVE DUST AND HAD A VERY DIRTY FILTER AT TIME OF INSPECTION. INDOOR COIL HAS BEEN PREVIOUSLY CLEANED AND STILL APPEARS CLEAN BUT THERE IS LOTS OF DUST IN THE REST OF THE UNIT


Keith H.

Keith H. Job Checkin

PERFORM PMP HEATING INSPECTION. DIAGNOSIS- UNIT IS HEATING JUST FINE. TESTED FREON LEVELS. AMP DRAWS ON MOTORS. TESTED RUN CAPACITORS. TIGHTEN ELECTRICAL CONNECTIONS. TESTED HEATING DEFROST CYCLE AND AT THIS TIME RUNS PERFECTLY. - REPLACED THE 30X20X3 IN FILTER WITH NEW AND SUPPLIED 1 EXTRA. UNIT IS RUNNING IN HEATING JUST FINE. NO REPAIRS NEEDED AT THIS TIME.


Chris R.

Chris R. Job Checkin

PROBLEM NO HEAT TRANE DIAGNOSIS TRIPPED BREAKER RESET BREAKER /RAN UNIT FOR 10 MINUTES WITH NO ISSUES WE WILL NOT CHARGE FOR THIS TRIP BUT IF WE NEED TO COME BACK THERE WILL BE A DIAGNOSTIC FEE UNIT IS HEATING AT THIS TIME


Keith H.

Keith H. Job Checkin

THE OUTDOOR UNIT DEFROST CONTROL BOARD IS NOT WORKING CORRECTLY. THE BOARD SHOULD BE REPLACED TO ALLOW THE SYSTEM TO SEQUENCE THRU DEFROST TO PREVENT THE UNIT FROM BECOMING DAMAGED IN THE COLD WINTER MORNINGS. THE BOARD AND THE SENSORS SHOULD BE REPLACED AT THE SAME TIME. THE CURRANT SENSOR IS OFF BY ABOUT 7 DEG. AND THIS COULD CAUSE THE UNIT TO NOT CYCLE THRU DEFROST AT THE CORRECT TEMPATURES. 11-27-18 REPAIR- REPLACED DEFROST CONTROL BOARD AND SENSORS. THE UNIT NOW CYCLES THRU DEFROST UNDER THE NORMAL DEMAND SEQUENCE OF OPPERATION. NO OTHER REPAIRS NEEDED AT THIS TIME.


Keith H.

Keith H. Job Checkin

Performed route maintenance for a customer in Peoria, Arizona found the defrost board to be faulty and recommend replacing it. Repair is schedule for 11/27/2018 from 1-5 pm.