725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Job Locations
for plain city, oh


Map of Plain City OH
Graham M.

Graham M.


Job Checkin

Gas heating preventative maintenance performed basement/first floor Check filter - due soon Clean flame sensor Inspect burners - clean no concerns Ohm test igniter: 58 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: new today Inspect exhaust flu - 2” - 3” pvc Set thermostat for heat Check amp draw on blower motor: 3.02 Check amp draw on inducer motor:0.33 Check delta T - 47 Furnace is in optimal running conditions Gas heating preventative maintenance performed 2nd floor Check filter - 20x25x4 ok Clean flame sensor Inspect burners - no concerns Ohm test igniter: 54 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a 2nd floor closet Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 1.43 Check amp draw on inducer motor:0.25 Check delta T - 56° Furnace is in optimal running conditions