Tech asked and listened to my preferences. Took great care with shoe covers, and my pets. I’m completely pleased with my estimate.
Josh was very knowledgeable with all the options. He went through different options for me and explained each option. He asked a lot of questions to figure out which one would be the best option for me. He did all the figuring out part with me so it was easy for me to figure out which one would serve me the best!
Great information - answered all of my questions. After comparing Train, Lennox and Carrier for quality, efficiency, warranty, and cost I went with Carrier and Xenia Heating and Air.
After removing the Rheem gas furnace and air conditioner, I installed a Five Star 95% 60,000 BTU Gas Furnace 3.5T 17" and a Five Star 13 SEER 3 Ton Air Conditioner. Cycled and monitored the system. Operating normally at this time. Included with the installation is a free 1 year service maintenance agreement.
I arrived to perform a diagnostic on an air conditioner. Found filter clogged 16x25x1, removed and customer to replace ASAP. Found outdoor unit 100% clogged, cleaned. Unit now cooling suction 73. System past normal life span, informed customer.
After removing the Goodman air conditioner, I installed a Five Star 13 SEER 3 Ton Air Conditioner. Cycled and monitored the system. Operating normally at this time. Included with the installation is a free 1 year service maintenance agreement.
After removing the Lennox gas furnace and Rudd air conditioner, I installed a Five Star 80% 70,000 BTU Gas Furnace 3T 17" and a Five Star 13 SEER 2.5 Ton Air Conditioner. Cycled and monitored the system. Operating normally at this time. Included with the installation is a free 1 year service maintenance agreement.
I completed a diagnostic service call on an air conditioner. I determined that the unit's contactor was not receiving proper voltage. Once I corrected the shortage, I cycled and the unit is now operating properly.
I completed a return service on a five star air conditioner. I determined that there was a piece of paper stuck behind the blower cabinet. I removed the paper and cycled. System is now operating as intended.
I completed a diagnostic service call on a Kenmore gas furnace. I determined that the unit was in need of a new capacitor and blower motor. I went over the options with the customer.
Client requested an estimate to replace a 20 year old air conditioner. I recommend replacing it with a Five Star 13 SEER 2 Air Conditioner. Included in the estimate is a 1 year free service maintenance agreement.
I removed a Williamson low boy Gas Furnace. I installed a Five Star 80% 70,000 BTU Gas Furnace and a Five Star 13 SEER 2.5 Ton Air Conditioner. Cycled and monitored the system. Operating normally at this time. Included with the installation is a free 1 year service maintenance agreement.
I completed the scheduled maintenance agreement cooling tune up on a Five Star air conditioner. I visually inspected the unit. Checked voltages, amps and pressures. I inspected the evaporator coil. I checked the temperature difference across the coil. Inspected heat pump. Checked refrigerant charge, voltages and amps. I rinsed the condenser coils with water. Cycled and monitored system. All operating normally at this time.
I gave an estimate to replace Bryant air conditioner. I recommend replacing it with a Five Star 13 SEER 2 Ton Air Conditioner and Aprilaire 400 Humidifier. Included in the estimate is a 1 year free service maintenance agreement.
I gave an estimate to install a Five Star 13 SEER 2.5 Ton Air Conditioner. Estimate included 1 year of Scheduled Maintenance agreement.
I returned to recheck Heat Pump on a 2015 American Standard Electric Furnace and heat Pump. I determined that the system was flashing a lockout code, reset system. System is operational at time of departure.
I completed fall tune up on a 2013 Nordyne Gas Furnace visually inspected the furnace. Checked voltages, amps and temperature rise. Inspected heat pump. Checked voltages and amps. Cycled and monitored both systems. Operating normally at this time.
I completed a diagnostic on a 04 Carrier Gas Furnace. Determined that multiple issues discussed with customer and recommended that due to the age, condition and cost of repairs that the unit be replaced.