you're asking me to give you feedback on Christian Rice, he did not perform the work. O my God do you even know who you sent here?
Chris did a good job and identified that the wiring was incorrect and rectified the problem.
Comfort Solutions installed and now maintains my AC unit and does an awesome job. I don’t have to worry about remembering to schedule as their Customer Service team is great about keeping me up to date on maintenance. Thanks everyone!
Tech even showed up early which was appreciated. Respectful and friendly. Knew his business.
Technician found grounded compressor in the outdoor unit for the downstairs system. We are actively awaiting response from manufacturer to check warranty status of equipment. Once the warranty status has been confirmed, we will provide estimate either for repair if it is under warranty. However, if it is not under warranty, we will be still providing an estimate for replacement.
1 system CCM- Checked heating operations of Duel fuel 2014 Rheem furnace and heat pump. Replaced 16x25x1 filter, Checked capacitor outputs and amp drawls, Checked refrigerant levels and auxiliary heat, Triggered safety switches and defrost mode, Checked delta T, and cleared drain line. System is operating properly at this time. Pics uploaded Also recommended a drain safety switch, new condensation pump and a carbon monoxide detector. Customer approved the BEST option with installing all 3, Has a 1yr warranty on parts
I have an estimate for moving the 3rd sidewall cap , customer approved estimate. We will schedule a return visit as soon as we get the materials in. I also made adjustments for the air flow,customer said the adjustments helped but still need move. I will check back with the customer on the return visit to see how the adjustments worked.
Check start capacitor. 80/5. capacitor checked good 79.6/4.7. Need Outside condenser motor. Jasons ordering Motor
Performed 2 heat pump system maintenances. Replaced both 16x25x4 media filters. Checked blowers, heat kits, capacitors and system operation. Both systems are operating properly.
Completed replacement of 10” and 12” Honeywell supply dampers for 2 zones. I tested function of dampers and then tested at each thermostat. I completed a single system heating maintenance. I replaced 1-16x25x1 filter at furnace filter rack. I cleaned the flame sensor and checked the igniter. I checked the amp draw on the blower motor and capacitor. I checked all safeties and confirmed proper sequence of operation. The system is currently heating at manufacturers specifications.
Multihead, mini split. System does have refrigerant, condensers labeled factory charge. We still want to check the refrigerant levels. Temperature really needs to be 65-70° outside for accurate measurements. Office Will work with customer to schedule visit on day with warmer weather.
Performed single system heat maintenance cleaned flame sensor and pressure tube tested all electrical components and connections inspected gas and exhaust supply all systems operating properly at this time
Replaced 4-16x25x2, 2-20x35x2 filters and a AX36 belt. Systems are working properly. Pics uploaded, need extension ladder every visit Sending invoice to email for payment
Motor is ceased on to blower wheel cannot replace will be bringing motor to shop to attempt removal if removal is successful will return to complete motor replacement if removal is not successfully will have to replace motor wheel and housing estimate has been sent to customer and issues have been discussed
Performed 2 system maintenance. Upstairs is a heat pump system. Checked 16x20x5 media filter and is still in good condition. Checked components and operation and system working properly. Main floor has a natural gas furnace. Checked 16x25x5 media filter and is still in good condition. Checked components, blower motor, burners and heat exchanger. Furnace is working properly. Will need to replace filters next visit.
Change filter. Clean drain. Checked all electronic components. Checked amps on heat strip and blower. Both test fine. Check zone dampers. Both Damper test fine. fix insulation around line set. Checked amps on compressor and fan. Both test fine. He pop performing as it should.
During today’s visit, performed inspection and maintenance on one attic air handler, and one outdoor heat pump unit. Inspected ductwork. inspected overall cleanliness of the blower and coil compartments. there is mold and mildew buildup inside the blower compartment. Photo attached. Recommend ultraviolet lighting to combat the buildup. Estimate sent the customer. Inspected blower amp draws. Inspected temperature Heat rise in normal heat mode. Inspected functionality of auxiliary heat strips. Inspected outdoor unit. Electrical components. All measurements are within specifications And the system is functioning normally at this time.
Performed maintenance on two systems. Gas furnaces with AC cooling. Upstairs filter is still acceptable. Upstairs system does not operate very much. The downstairs filter will be ready for replacement on next visit 16 x 25 x 5. Please have the technician bring a filter with them if she is not able to find them on her own. Inspected electrical connections and components. Treated condensate drain lines with chlorinating tablets. Cleaned flame. Sensors of gas furnaces. Inspected operations and units currently are functioning properly.
2 system CCM- Checked heating operations of upstairs 1993 Trane, and Main level 2019 Rheem furnaces. Replaced 2-16x25x1 filters, Checked capacitor outputs and amp drawls, Inspected heat exchangers, Checked delta T, triggered safety switches, Cleaned flame sensors, Brushed burners, and cleared drain line. Systems are operating properly at this time. Pics uploaded Customer would like to schedule to add a Pan safety switch(upstairs), replace weak 5mfd capacitor(upstairs), replace corroded flu pipe for the main level system, and add a carbon monoxide detector in home.