Jordan E.

Jordan E. Job Checkin

Filter needs to be changed next visit. Check the electronic components. Clean drain. Checked zone dampers Boat zone dampers working as they should. Check pan switch and condensation switch on pump. Checked amps on outside compressor and fan. Both test fine. Heat pump performing as it should.


Jordan E.

Jordan E. Job Checkin

Downstairs unit. Change filter. Clean drain. Checked amps on heat strip and blower motor. Both test fine. Checked amps on compressor And fan. both test fine. Heat pump run as it should. Upstairs unit. Change filter. Clean drain. Checked amps on heat strip and blower motor.bothTest fine. Checked amp draw on outside compressor and fan. both test fine. Heat pump running as it should.


Jordan E.

Jordan E. Job Checkin

I completed a two system heating maintenance. I replaced 3-14x20x1 filter at filter return grills. I checked the amp draw on the blower motors and heat strips. I tested safties and conf Proper sequence of operation. I checked amp draw on the outdoor unit ,checked defrost cycle and checked capacitors. Systems are currently heating at manufacturers specifications.


Jordan E.

Jordan E. Job Checkin

I completed two system heating maintenance. I replaced media filter and 1” filter. I checked amp draw on all units and confirmed proper sequence of operation. I checked function of heat strips and proper amp draw. Systems are currently heating at manufacturers specifications.


Jordan E.

Jordan E. Job Checkin

Performed single system heat maintenance 20x20x5 filter was new checked electrical components and connections as well as zone functions and refrigerant charge all systems operating properly at this time


Jordan E.

Jordan E. Job Checkin

Change filter. Checked amperage on heat strip and blower motor. Both tested fine. Heat pump performing as it should.


Jordan E.

Jordan E. Job Checkin

Bad zone board. Put New zone board on. Unit working as it should.


Jordan E.

Jordan E. Job Checkin

Quote


Jason  J.

Jason J. Job Checkin

Quote


Jordan E.

Jordan E. Job Checkin

Performed 2 system cooling maintenance 16x20x5 filter is still good 14x20x1 filters are new checked electrical components and refrigerant charge all systems working properly at this time


Jordan E.

Jordan E. Job Checkin

Performed 1 system ccm cooling maintenance replaced customer provided 16x20x4 filter checked electrical components and refrigerant charge all systems operating properly at this time


Michael  J.

Michael J. Job Checkin

Found basement system, condensate removal pump unable to pump water. Replaced condensate removal pump with new pump. Flushed all drain lines to ensure water flow. Also vacuumed water from emergency pan. Also tied in the new pump safety float switch so that if pump were not able to remove water, it would shut down system before water overflows.


Jordan E.

Jordan E. Job Checkin

Finished up dryer vent. Strap ductwork back up. Fix vent hood duck in attic. Cabinet people did not cut holes in cabinets for Toe kick. Vent hood not installed could not hook it up. Left 5 foot of 6 inch pipe.Left Toe kick Grill.


Michael  J.

Michael J. Job Checkin

Found low voltage short in air handler that I believe may have caused the issue, or possibly some sort of high-voltage/brown out backfeed may have occurred. Made repair at low-voltage in the air handler. Replaced fuse and replaced thermostat. Technician also inspected outdoor unit for any potential electrical feed issues. System is now cooling normally.


Kyle W.

Kyle W. Job Checkin

System is running and cooling as should. Filter size is 16x20x1” PUMP IS NOT PLUGGED IN DO TO NO OUTLET 5/16 builder knows. Toe kick at garage entry is not cut into kick plate of cabinets, builder was also told about this as well. Ran out of Freon and system is charged just might be a little low. 6” hood vent needs connected in attic. 3- 6” elbows and tape.