Warranty- Arrived and found the basement system not going into defrost mode,even when I forced it. I found the y wire from the defrost board bypassed and t1 terminal not connected to the contractor. This was not allowing the unit to enter defrost mode. I corrected the wiring and system goes into defrost mode now.


Jordan E.

Jordan E. Job Checkin

Performed 3 system heat maintenance replaced 1 20x25x1 1 14x14x1 and 1 16x20x1 filters cleaned flame sensors and pressure tubes tested all electr Components tested auxiliary and thermostat functions as well as refrigerant charge found a failed capacitor on heat pump for basement system preventing operation of compressor replaced 35/5 capacitor system are operating properly at this time


Jordan E.

Jordan E. Job Checkin

I performed a 2 system maintenance on two heat pumps I did not have to change the filters they are two 16x25x5 homeowner is going to provide them. I look at all the low voltage took the blower motor amperage inspected the heat strips. I checked the charge and the compaster on both systems. The system are runs and operating like they should be at this time


Jordan E.

Jordan E. Job Checkin

Install new 2-wire gas valve for natural gas furnace. I installed in gas valve and tested the system. System is now heating correctly with new gas valve installed.I completed a single system heating maintenance. I replaced 1-14x25x1 filter. I checked amp draw on the blower motor and checked the capacitor. I cleaned the flame sensor and checked the igniter. I checked safeties and confirmed proper sequence of operation.


David J.

David J. Job Checkin

Furnace has bad gas valve. Will have to get new 2-wire valve for replacement. Will be sending estimate for repairs.


Jordan E.

Jordan E. Job Checkin

Called no answer we’ll need to reschedule


Jordan E.

Jordan E. Job Checkin

I performed a maintenance on two gas furnace in the attic. I looked at all the low-voltage clean the flame sensor checked the blower motor amperage checked the capacitor on both systems and changed the filter with a homeowners filter 16 x 25 x 1. The systems are running and operating like they’re supposed to at this time.


Alex S.

Alex S. Job Checkin

Warranty- System we installed March 8th, 2023 is working properly. I did inspect everything and only issue I found is that the installers did not turn off outdoor sensor on the T6 thermostat (AC is not equipped with one). 16x25x5, pics uploaded Is aware about warranties and memberships


Michael  J.

Michael J. Job Checkin

Sound that was being heard in the back operational room was caused by heavy airflow. Technician located manual air volume damper, on ductwork and adjusted airflow down to reduce sound. Technician also made observation that the equipment does not appear to have had any maintenance since installation having original filters that come with the equipment. Technician highly recommends that all three systems be serviced thoroughly, including replacing filters and belt replacement and/or adjustments. Estimate for maintenance of the systems will be provided via email.


Jordan E.

Jordan E. Job Checkin

ZERO percent interest financing for 36 months WAC


Jordan E.

Jordan E. Job Checkin

Completed one system cooling maintenance. I replaced customer provided filter,cleared drain line and checked all electrical components on the indoor unit. Cleaned outdoor unit,checked charge and checked all electrical components. System is currently cooling at manufacturers specifications. Outdoor unit was extremely clogged with grass. I highly recommend either changing mowing directions or turning the thermostat mode to off while cutting the side yard.


Jordan E.

Jordan E. Job Checkin

ZERO percent financing for 36 months WAC


Jordan E.

Jordan E. Job Checkin

System was approprimately 3 pounds over charge recovered refrigerant and suction pressure was still high couldn’t find any obvious issues system is now cooling recommended ac upgrade due to weak compressor customer enrolled into maintenance program so no charge


Jordan E.

Jordan E. Job Checkin

ZERO percent interest financing WAP


Jordan E.

Jordan E. Job Checkin

Located horizontally in the attic with plenty of clearance