Alex S.

Alex S. Job Checkin

2017 Goodman Heat pump not working because of a shorted compressor. The 5yr Goodman manufacturer warranty is expired(we do not replace compressors out of warranty). System replacement is recommended. Pics uploaded. Customer is interested in quotes, 16x20x1 Sending invoice to email


Jordan E.

Jordan E. Job Checkin

Homeowner had an emergency needed to cancel


Alex S.

Alex S. Job Checkin

1 system PM 2nd visit- Checked heating operations of system. Replaced 16x25x5 filter, checked capacitor outputs and amp drawls, Inspected heat exchangers, Checked delta T, triggered safety switches, cleaned flame sensor, cleaned burners, and cleared drain line. system is operating properly at this time. Pics uploaded Sending invoice to email for payment


Jordan E.

Jordan E. Job Checkin

I performed a maintenance on a one system, gas furnace in the crawlspace. I looked at all the low-voltage checked the blower motor amperage blew out and treated the drain line. I checked the charge, the capacitor and washed out door system off. The system is running and operating like it supposed to at this time.


Jordan E.

Jordan E. Job Checkin

Arrived and found blower motor not running on a cool call. Diagnosed bad blower motor. Installed new universal blower,mounting bracket and capacitor. I tested system function. Blower is operating correctly and system is currently cooling the house.


Jordan E.

Jordan E. Job Checkin

Customer reports system not cooling upon inspection found evaporator coil to be frozen due to a damaged blower motor drive belt also found one of the compressors had a psi reading of 0 added refrigerant to perform leak search and found leak at the internal connection for wiring plug attached to compressor compressor will not hold refrigerant can not replace compressor due to it being out of warranty system replacement is recommended email has been sent for comfort advisor to perform estimate on system replacement


David J.

David J. Job Checkin

Upon arrival no high voltage to condenser unit, tripped breaker because of loose wire connection. Reset breaker and condenser came on. Checked refrigerant levels and system has low suction pressures, customer isn’t aware of any filtration on the system. More than likely evaporator coil is clogged. Crawl space has fleas and the customer will be exterminating before it can be checked. Will call when crawl has been exterminated.


Jordan E.

Jordan E. Job Checkin

Install new Rheem 3 phase 5 ton a/c unit with matching Rheem 5 ton evaporator coil.


David J.

David J. Job Checkin

Upon arrival, customer explained that it would cool intermittently. After further inspection of system found that compressor for system is pulling higher amps than normal run amps. Unit is 28 years old and at the end of its life. Highly recommend replacing. Will be emailing estimates for replacement. System is 5 ton 3 phase cooling with 100k btu natural gas 80% furnace. Furnace is only 8 years old and operating normally. Pricing for replacement will have crane rental included.


Jordan E.

Jordan E. Job Checkin

Arrived and discussed issue with customer. Diagnosed bad condenser fan motor , outdoor disconnect is in the off position. Fan will run when it is cooled down but over heats,shuts off and will not restart. Condenser fan motor will need to be replaced and we need to finish cooling maintenance (clean out door unit and check charge). Estimate will be sent for the outdoor condenser fan motor.


Jordan E.

Jordan E. Job Checkin

I performed a one time maintenance on a single stage heat pump. I look at the low voltage and the treated the drain line, I checked the blower motor. I checked charge and the compaster. The system is running like it should be


David J.

David J. Job Checkin

No water in any of the 3 system’s safety pans. Customer must’ve been seeing the water that was soaked into insulation seeping back out into pan. Issue was resolved last visit with cleaning the buildup off of the evaporator coil for main floor system. Systems are working properly.


David J.

David J. Job Checkin

Evaporator coil for main floor system was clogged causing unit to freeze and fill up the safety pan. Cleaned evaporator coil and checked refrigerant, system operating properly.


Jordan E.

Jordan E. Job Checkin

Installed emergency drain pans under the main level and basement indoor air handler‘s so that if there is ever a water issue, the water will be contained to the pans and not be able to spread to any finished areas or sheetrock. Also installed a Honeywell T4 thermostat for the basement Goodman air handler. Pics uploaded. Systems are working properly. Sending invoice to email for payment


Michael  J.

Michael J. Job Checkin

Re-inspection of three systems. The upstairs system is heating and cooling properly and does not have any other issues that need to be addressed. The mid/main level system is now heating and cooling properly. Low-voltage wiring at thermostat was preventing the auxiliary heat strips from operating, causing the auxiliary heat not to operate. If thermostat was cranked up. This issue has been resolved. The basement system outdoor unit needs 220 V power in order to operate as per our previous visit. An electrician is going to be repairing this issue and once repaired heating and cooling Will operate normally for the basement. The drain line for the upstairs unit outside was extended as per the inspection report, as well as the insulation on the lineset has been patched and repaired. Our office will be providing an estimate for the addition of two auxiliary/emergency pans with float switches to be put underneath both the main level air handler in the basement air handler so that if there’s