Replaced bad air handler high voltage disconnect box. Afterwards heat pump wouldn’t run so had to locate zoning panel, which is located in hallway closet upstairs. Zone panel was set for emergency heat only, turned switch off so that it would run the heat pump and electric heat kit for backup. System is now operating properly.
I performed a heat maintenance on a gas furnace.I looked at all the low voltage, checked the blower motor amperage, cleaned the flame sensor and changed the filter 16x25x1. The system is running and operating like it should be at this time.
Warranty- Mini split is heating, just had to explain and show customer how the vane and blower speeds worked on remote.
ZERO percent interest financing for 36 months with approved credit
Customer completed CCM form for three systems today. Performed heating maintenance on three systems. Upstairs and main level are located in the attic and are gas furnaces. The basement system is located in the basement and is a heat pump. Upstairs and main level systems can utilize 16 x 25 x 1 filters or 20 x 25 x 1 filters. Both have older April, air filter housings. Basement system has a 15 x 20 x 1 washable filter. Filter must be washed because other filter sizes will fall down and not fit properly. Cleared and treated condensate drain lines. Inspected electrical connections and components. Technician did show homeowner basement thermostat in effort to avoid emergency heat position. All three systems are operating normally at this time.
1 system PM 2nd visit- Checked operations of 2017 Rheem heat pump/air handler. Replaced 16x20x1 filter, Checked capacitor outputs and amp drawls, Checked refrigerant levels and auxiliary heat, Triggered safety switches and defrost mode, Checked delta T, and cleared drain line. System is operating properly at this time. Pics uploaded
Replace blower motor under parts warranty. Only labor will be charged.
Replace blower motor under parts warranty. Only labor will be charged.
I performed a one system maintenance on a gas furnace, and a closet. I treated the drain line and blew it out. Check the blower motor amperage. I check the charge and the capacitor and I also washed the outdoor system. Mom change the filter 16 x 25 x 1 system was not running because of condensation pump being full and not being able to run out. Homeowner has a bad outlet
I performed and one system zone system I look over all the low voltage and the blower motor treated the drain line and charged the filter 16x20x1. I checked the charge and the compaster and washed the out door system off as well.
The damper for downstairs is stuck open and It will not allow it to close pulled it is the older stile damper so it will need to be replaced with a new 10 inch honeywell damper motor
Condenser capacitor was not functioning properly causing the compressor to not operate replaced with 45/5mfd capacitor
Condenser fan is currently not running do to a failed capacitor due to age and condition recommend replacement of contactor as well
Arrived and discussed issue with tenant. Found emergency drain pan at indoor unit full of water. Water came from unit freezing up due to low refrigerant charge. I spoke with customer and sent over estimates for repair options and discussed scheduling an appointment with our company advisor. Customer did not go with repairs at this time and wants comfort advisor to give estimate on system change out For this location. Cleaned water out of emergency drain pan and contacted office to schedule comfort advisor.
The wire for the compressor was bar and had to be stripped back and fix. I also installed a nest thermostat for the homeowner the system is running and cooling like it should be at this time