Jordan E.

Jordan E. Job Checkin

Performed single system heat maintenance replaced 16x20x1 filter tested auxiliary and thermostat functions tested all electrical components and connections as well as refrigerant charge all systems operating properly at this time


Michael  J.

Michael J. Job Checkin

Replace 5kw heat strips for basement 2009 Goodman air handler. After installing new new 5KW heat strips for basement Goodman air handler. Technician tested them to ensure that they are now working and to burn off the new smell that they make the first time they have operated. Unit is now operating normally.


Jordan E.

Jordan E. Job Checkin

Performed 3 system heat maintenance replaced 2 aprilaire 213 and 1 16x20x1 filters tested auxiliary and thermostat functions cleaned flame sensors and pressure tubes tested all electrical components and refrigerant charge customer has 3 Uv lights that need bulbs replaced other than that all systems operating properly at this time


Alex S.

Alex S. Job Checkin

2008 Basement Goodman air handler not maintaining temperature when outside ambient temperatures reach freezing because of shorted 5kw heat strips. Customer approved the GOOD option with just the heat strip replacement. Will be ordering from supplier. Pics and quotes uploaded


Michael  J.

Michael J. Job Checkin

Performed single system, heat pump maintenance. Replaced the 23 x 20 x 1 filter. Cleared condensate drain line. Customer has been treating with bleach. I did inform customer that vinegar is also effective and less caustic. Inspected refrigerant level of system. The sound end wetness the customer had noticed is all a part of the defrost cycle. Technician was able to observe a defrost cycle while on site and system is defrosting normally. Electrical wiring and amp draws of the unit are also normal at this time and system is maintaining thermostat temperature normally.


Jordan E.

Jordan E. Job Checkin

Install new 2 ton 14.3 seer2 cooling system with 50k btu 80% natural gas furnace.


Jordan E.

Jordan E. Job Checkin

Warranty. There was a return grill closing itself all the way creating a return air restriction in the system causing thumping in the plenum when the unit cycled on and off. This grill was right by the attic stairs. I made correction to the grill and also fired off the heat. System is operating correctly now.


Jordan E.

Jordan E. Job Checkin

I completed a two system heating maintenance. I replaced -116x25x1 filter and a provided 16x25x5 media filter. I checked amp draw on blower motors and inducer motors. I checked safeties and capacitors. I cleaned flame sensors and checked igniters. I confirmed proper sequence of operation. Systems are currently heating at manufacturers specifications.


David J.

David J. Job Checkin

Upstairs furnace control board not working properly. Due to age of system, it is recommended to upgrade to newer more efficient system. Will be sending email for pricing to repair or replace system.


David J.

David J. Job Checkin

Warranty!!! Thermostat not wired correctly on main floor thermostat. Moved white wire to w terminal in thermostat. System now operating properly.


David J.

David J. Job Checkin

Checked refrigerant levels for main floor system, system out of refrigerant and holds 4 lbs of refrigerant. Will be sending estimates for replacement of cooling system and complete system.


Jordan E.

Jordan E. Job Checkin

Completed 3 system cooling maintenance. I checked all air filter,checked all electrical components and cleared drains for indoor unit. Checked


Jordan E.

Jordan E. Job Checkin

Add 1 return vent in office


Jordan E.

Jordan E. Job Checkin

Replaced warranty coil for 5 ton down flow and 12.5 pounds of refrigerant to factory charge system is now cooling


Jordan E.

Jordan E. Job Checkin

2.5 ton system had a dirty filter. Replaced with 16x25x2 filter. System cannot condition the space due to the 5 ton system not operating due to the coil we are still waiting on from our supply house.