Daren O.

Daren O.


Job Checkin

CONCERN: Customer reports R/F coil cooktop burner is not working. DIAGNOSTIC AND CAUSE: Inspected for proper voltage from wall to cooktop terminal block, voltage is normal. Inspected voltage from terminal block to the main control input line, voltage was normal. Inspected voltage from the main control to the infinite input, voltage was normal. Inspected voltage from R/F infinite switch to the burner receptacle, found the burner receptacle shorted.CORRECTION: Replaced R/F burner receptacle, operation now normal.