CONCERN: Customer reports WHIRLPOOL Refrigerator is not cooling properly. Model GX5FADXVY04 DIAGNOSTIC AND CAUSE: Test compressor operation to see if the compressor was running. Compressor is running. Found evap is covered in ice. CORRECTION: Replaced ADC main control board and bi metal thermostat. Tested. Operation now normal.