Map of Tempe AZ
David R.

David R.


Job Checkin

CONCERN: Customer states washer is not working properly. DIAGNOSTIC AND CAUSE: Inspected wall receptacle for proper outlet voltage to washer, wall receptacle voltage is normal at the time of inspection. Inspected washer controls for proper input voltage, voltage normal at time of inspection. Inspected washer interlock continuity, found washer interlock switch failed. CORRECTION: Replaced washer interlock switch and tested on all cycles, operation now normal. CONCERN: Washer door does not close properly. CAUSE: Found door hinge bracket stripped/failed. CORRECTION: R&R door to repair door hinge bracket and tested. Operation now normal.