CONCERN: Customer reports refrigerator seems to run all the time. CAUSE: Found condenser coils clogged with debris. CORRECTION: Clean condenser coils and tested, operation now normal.


Company Owner .

Company Owner . Job Checkin

CONCERN: Customer reports microwave is not heating CAUSE: Magnetron and diode failure. CORRECTION: Replaced magnetron and diode. Operation now normal.


Company Owner .

Company Owner . Job Checkin

CONCERN: Customer reports GE refrigerator is not as cold as it should be. Model GSS25WTIBB DIAGNOSTIC AND CAUSE: Inspected wall outlet for proper voltage output, voltage output normal at the time of inspection. Inspected for voltage input at the compressor, compressor voltage input normal at the time of inspection. NOTE: Compressor was running and cooling unit down. Inspected voltage input at the condenser fan motor, input voltage was normal at the time of inspection. Found condenser fan motor Locked up and not running. CORRECTION: Replaced condenser fan motor and tested. Operation now normal. NOTE: Also adjusted evaporator fan motor blade and cleaned condenser coils


Paul  S.

Paul S. Job Checkin

CONCERN: Customer reports GE L/F Glass cooktop burner is not working. Model JBP72B0K1BB DIAGNOSTIC AND CAUSE: Inspected cooktop for proper voltage from supply line, voltage is normal. Inspected cord to terminal block for signs of failure, cord to terminal block is normal. Inspected voltage output from control to infinite switch, voltage to infinite switch is normal. Inspected voltage from infinite switch to burner, voltage from infinite switch to burner is normal. Inspected burner receptacle, receptacle is normal. Inspected and performed Ohms test on burner, found burner assembly failed. CORRECTION: Replaced L/F Glass cooktop burner and tested. Operation now normal.


Paul  S.

Paul S. Job Checkin

GE Refrigerator not cooling. Honeycutt/Porter MOD: ESS25QSWASS Part# WR55X10942 CONCERN: Customer reports refrigerator is not as cold as it should be and the center divider is hot to the touch.CAUSE: Found condenser fan motor pushed too far forward. CORRECTION: Repaired condenser fan motor and tested. Operation now normal.