Carlos is a fantastic repair expert with a huge amount of knowledge. Don, the owner, is very helpful and eager to see his customers taken care of in record time. We are very impressed by this company and will refer them to our friends. We would call them again for any appliance issue that we may have. Thanks guys! Lou

  • Overall Experience
  • Quality
  • Price
  • Convenience

Quick to find the problem.

OK and will use again if needed.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for sun city, az

Paul  S.

Paul S. Job Checkin

Refrigerator service call. No repairs made at this time. Found broken water valve recommended plumber to replace valve.


Company Owner .

Company Owner . Job Checkin

CONCERN: Dryer takes too long to dry clothes, dryer does get hot though. DIAGNOSTIC AND CAUSE: Tested dryer for proper heater element operation. Heater operation is normal. Inspected heater thermostat operation for short cycling condition, thermostat is short cycling. Inspected dryer air flow at the duct flume, air flow is normal at this time, no signs of flow restriction. Cause, Wall vent clogged with lint. CORRECTION: Performed dryer vent cleaning, tested for restrictions, operation now normal


Company Owner .

Company Owner . Job Checkin

CONCERN: Customer reports Refrigerator is not cooling properly. DIAGNOSTIC AND CAUSE: Test compressor operation to see if the compressor was running. Compressor was not running. Tested for voltage from adaptive defrost control board to compressor. No voltage from the main control board to the compressor. Cause of failure found ADC main control board shorted at the output line voltage to the compressor. CORRECTION: Replaced ADC main control board and tested. Operation now normal.


Company Owner .

Company Owner . Job Checkin

CONCERN: Refrigerator is not working properly. DIAGNOSTIC AND CAUSE: Inspected wall outlet for proper voltage, voltage at wall outlet was normal at the time of inspection. Inspected input voltage to compressor, input voltage at compressor was normal at the time of inspection. Inspected refrigerator thermostat cold control operation, found refrigerator cold control failed. CORRECTION: Replaced refrigerator cold control and tested. Operation now normal.


Company Owner .

Company Owner . Job Checkin

CONCERN: Customer reports microwave is not Turning off . RECOMMEND: reset microwave.


Company Owner .

Company Owner . Job Checkin

CONCERN: Customer reports that the Refrigerator is not getting cold in either compartment. CAUSE: Inspected wall voltage for proper output, voltage output is normal. Inspected compressor for proper voltage, voltage to compressor is normal. Inspected compressor starter for proper continuity, no continuity at the compressor starter. Tested compressor windings for electrical shorts, no shorts at compressor windings. CORRECTION: Replaced compressor starter and tested. Operation now normal. CONCERN: Refrigerator section is not getting cold. DIAGNOSTIC AND CAUSE: Inspected voltage from terminal block to compressor, voltage normal at the time of inspection. Tested compressor operation, compressor operation normal at the time of inspection. Inspected voltage to evaporator fan motor, voltage normal at the time of inspection. Found evaporator fan motor failed. CORRECTION: Replaced refrigerator evaporator fan motor and tested. Operation now normal.


Company Owner .

Company Owner . Job Checkin

CONCERN: Customer reports MAYTAG Refrigerator is not cooling properly.Model MFI2269VEM3 DIAGNOSTIC AND CAUSE: Test compressor operation to see if the compressor was running. Compressor was not running. Tested for voltage from adaptive defrost control board to compressor. No voltage from the main control board to the compressor. Cause of failure found ADC main control board shorted at the output line voltage to the compressor. CORRECTION: Replaced ADC main control board and tested. Operation now normal.


Company Owner .

Company Owner . Job Checkin

CONCERN Customer reports refrigerator not dispensing water. CAUSE: Found bad control board CORRECTION: removed loose connection to board and tested. Only water dispensing.


Company Owner .

Company Owner . Job Checkin

(Misc.) CONCERN Customer reports refrigerator not closing CAUSE: Found door track come loose CORRECTION: re install door track and tested. Operation now normal.


Company Owner .

Company Owner . Job Checkin

CONCERN: Customer reports that the washer is not draining. DIAGNOSTIC AND CAUSE: Inspected wall outlet for proper voltage to washer, voltage output from wall outlet normal at the time of inspection. Inspected voltage output from control to washer drain pump, voltage to drain pump normal at the time of inspection. Found washer pump impeller was trying to turn however the technician found washer drain pump clogged with debris. CORRECTION: Removed drain pump to clear debris and re-installed, check for leaks and tested, Operation now normal.


Company Owner .

Company Owner . Job Checkin

CONCERN: Dryer is making a loud noise when tumbling. DIAGNOSTIC AND CAUSE: Inspected dryer barrel operation, operation normal. Inspected blower wheel for restrictions, no restrictions in or around blower wheel. Found dryer drum support rollers failed. CORRECTION: Replaced rollers, belt, and idler pulley. Operation now normal


Company Owner .

Company Owner . Job Checkin

CONCERN: Customer reports washer water inlet is not working properly. CAUSE: Found washer water valve failed. CORRECTION: Replaced washer water valve and tested. Operation now normal.


Company Owner .

Company Owner . Job Checkin

CONCERN: Dryer is making a loud noise when tumbling. DIAGNOSTIC AND CAUSE: Inspected dryer barrel operation, operation normal. Inspected blower wheel for restrictions, no restrictions in or around blower wheel. Found dryer drum support rollers failed. CORRECTION: Replaced rollers, belt, and idler pulley. Operation now normal


Company Owner .

Company Owner . Job Checkin

CONCERN Customer reports refrigerator is losing power intermittently & will restore power once you slam the door CAUSE: Found that the refrigerator is plugged into an outdated outlet. She is using a bypass plug that bypasses the ground pin CORRECTION: recommended she hires in electrician to correct the outdated Outlet..


Company Owner .

Company Owner . Job Checkin

CONCERN: Customer reports refrigerator is leaking water onto floor. DIAGNOSTIC AND CAUSE: Inspected water supply line to refrigerator for leaks, no leaks found at this time. Inspected water valve for leaks, found water valve failure. CORRECTION: Replaced water valve and tested. Operation now normal. CONCERN: Customer reports ice maker will not dispense ice. CAUSE: Found dispenser auger motor failed. CORRECTION: Replaced auger motor and tested, operation now normal.