Alex W.

Alex W.


Job Checkin

Customer was experiencing a power outage in certain bathrooms. The receptacles and the lights were out. I located the issue. Then I removed all receptacles in the bathrooms and the outlet outside on the front porch. I replaced them with tamper resistant GFCIs. I also rewired the boxes and line sided my gfcis so in the event a gfci were to trip it will not effect the lights or the other gfcis in the other bathrooms. I also noticed the breaker was not the correct amperage for the 14 gage wire. So I replaced it with a 15 amp CH breaker. I serviced the electrical panel and then I installed a weather resistant tamper resistant gfci outside on the front porch. I then used a in use bubble cover and siliconed around the brick to help protect the device from weather. This work comes with a 1 year warranty