Alex W.

Alex W.


Job Checkin

Customer had a previous contractor finish the garage and add two new receptacles then discovered their gfci in the powder room downstairs was tripping After diagnosing the issue the customer decided the gold option was the best interest So I removed all the receptacles on that circuit and replaced them with GFCIs In each box I spliced all the appropriate wires together and then pig tailed off the splice. This ensures the best possible connection for the circuit. I then installed tamper resistant GFCIs and line sided throughout all the new devices. I installed weather resistant tamper resistant GFCIs outside the home and installed in use bubble covers and broke the tabs off so they could plug in cords and shut the cover protection the male end of the cord and the device. I also repaired and re secured the boxes outside which were falling out of the walls I also installed a 15 amp cutler hammer Black and Tan arc fault breaker for this circuit I removed and replaced a keyless pull