Job Checkin

I isolated the circuit going from the side of the house out to a patio shed that use to have a hot tub in it. I also found the circuit feeding a disconnect for the hot tub. I turned off power to both then removed the disconnect and sealed the hole the wires were coming through the side of the home. I then cut the 14-2 UF cable feeding the receptacles in the patio then ran a piece of pvc up the wall on the side of the home and installed a weather proof box over the sealed hole the hot tub wires were coming through I then installed a weather resistant tamper resistant gfci and a in use bubble cover and then siliconed around the weather proof box. Then I removed the wires from the main electrical panel that powered the hot tub so there is no way they could ever be energized. Tuned the breaker back on for the gfci and tested it. I also demoed all the wires and devices in the patio area so the customers would feel safe working in there Customer has a 6 month warranty for all work preform